𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Basic matrices in the analysis of non-covalent complexes by matrix-assisted laser desorption/ionization mass spectrometry

✍ Scribed by Jespersen, S.; Niessen, W. M. A.; Tjaden, U. R.; van der Greef, J.


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
116 KB
Volume
33
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


A number of potential matrix candidates were investigated with regard to the importance of the pH in the matrixassisted laser desorption/ionization mass spectrometry (MALDI/MS) analysis of non-covalently bound protein complexes. The matrices examined were 2,5-dihydroxybenzoic acid (DHB), 4-hydroxy-a-cyanocinnamic acid (HCCA), 2-aminonicotinic acid (ANA), 4-nitroaniline (NA), 2-amino-4-methyl-5-nitropyridine (AMNP) and 3hydroxypicolinic acid (HPA). In solution these matrix compounds permitted the preparation of MALDI samples at pH in the range 2-7. Among the matrices tested, complex formation, by speciÐc non-covalent interactions, could only be observed when HPA (pH 3.8) was used as the matrix for the MALDI analysis. Under these conditions, speciÐc non-covalent complex formation of recombinant streptavidin and glutathione-S-transferases were observed but not for human hemoglobin. The MALDI spectra obtained with the neutral compounds ANA (pH 4.4), NA (pH 6.4) and AMNP (pH 7.1) as matrices contain only peaks of the subunit with no signal of the non-covalent bound complexes present. Considering the results obtained in this study with basic and acidiÐed matrix materials, there does not appear to be a strong correlation between the pH of the matrix solution and the utility of a matrix for the analysis of non-covalently bound complexes.


πŸ“œ SIMILAR VOLUMES


Quantitative Analysis of Oligonucleotide
✍ Bernd A. Bruenner; Tai-Tung Yip; T. William Hutchens πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 434 KB πŸ‘ 2 views

Quantitative aspects of oligonucleotide analysis by matrix-assisted laser desorption/iotion (MALDI) mass spectrometry remain largely unexplored relative to the efforts that have been devoted to quantitative peptide and protein analysis. The successful quantitation of these other biopolymers coupled

Analysis of wheat gluten proteins by mat
✍ Dworschak, Ragnar G.; Ens, Werner; Standing, Kenneth G.; Preston, Ken R.; Marchy πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 237 KB πŸ‘ 2 views

Matrix-assisted laser desorption/ionization mass spectrometry (MALDI/MS) was used to analyze the protein composition in several common and durum wheat varieties. Mass spectra were obtained directly from crude and partially puriÐed wheat gliadin and reduced glutenin subunit fractions. Mass spectra of

Analysis of DNA by β€˜Charge Tagging’ and
✍ Ivo G. Gut; William A. Jeffery; Darryl J. C. Pappin; Stephan Beck πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 200 KB πŸ‘ 2 views

We have developed a method to quantitatively attach quarternary ammonium fixed charge tags to the 5' or 3'NH 2 ends of DNA using N-hydroxysuccinimidyl ester chemistry. The chemical conditions for tagging were chosen so that tagging takes place exclusively on aliphatic NH 2 groups while base amino gr

Quantitative analysis of antibiotics by
✍ Yong-Chien Ling; Lihnian Lin; Yi-Ting Chen πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 242 KB πŸ‘ 2 views

Comparative studies of the matrix-assisted laser desorption/ionization (MALDI) of 30 antibiotics were made using a-cyano-4-hydroxycinnamic acid (HCCA), 2,5-dihydroxybenzoic acid (DHB), 5,10,15,20tetrakis(4-hydroxyphenyl)-21H,23H-porphyrin and meso-tetra(N-methyl-4-pyridyl)porphyrin matrices. Most an

The Analysis of Polysulfonated Azo Dyest
✍ Anthony G. Sullivan; Simon J. Gaskell πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 196 KB πŸ‘ 1 views

Electrospray ionization and matrix-assisted laser desorption/ionization have been applied to the analysis of polysulfonated azo dyestuff mixtures. Three homologous orange dyestuffs were synthesized using a harsh, two-stage process involving a condensation followed by a reduction and, producing compl