Base-induced transient isotachophoretic stacking of acidic drugs in capillary zone electrophoresis
✍ Scribed by Joselito P. Quirino
- Publisher
- John Wiley and Sons
- Year
- 2011
- Tongue
- English
- Weight
- 435 KB
- Volume
- 34
- Category
- Article
- ISSN
- 1615-9306
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Online sample concentration of acidic drugs by transient isotachophoresis (t‐ITP) with the injection of a base is described in capillary zone electrophoresis (CZE). A positively coated capillary was conditioned with background electrolyte (ammonium acetate at pH 6). A long plug of sample solution (S) prepared in ammonium acetate was then hydrodynamically injected followed by the base (tetrapropylammonium hydroxide). A negative voltage was applied and caused the hydroxide ions from the base to penetrate the S zone and created a pH junction that swept through the S zone. The analytes stack at the junction where the mechanism of focusing was transient ITP with the acetate and hydroxide ions as leading and terminating ions, respectively. The concentrated analytes separated in co‐EOF CZE once the hydroxide was exhausted. The base stacking strategy was tested using hypolipidemic, nonsteroidal anti‐inflammatory, and diuretic drugs, and afforded 19–37 improvements in peak height.
📜 SIMILAR VOLUMES
## Field-amplified sample stacking capillary zone electrophoresis applied to the analysis of opiate drugs in hair The present paper describes the methodological optimization and validation of capillary zone electrophoresis (CZE) for the determination of major opiates (morphine, codeine, 6-monoacet
## Abstract Large‐volume sample stacking (LVSS) is an effective on‐capillary sample concentration method in capillary zone electrophoresis, which can be applied to the sample in a low‐conductivity matrix. NaOH solution is commonly used to back‐extract acidic compounds from organic solvent in sample
## Abstract A CZE with indirect LIF detection method was used for the determination of uric acid (UA) in human urine. UA and its coexisting analytes (__i.e__. hypoxanthine, xanthine and ascorbic acid) could be well separated within 4.5 min at a voltage of 25 kV with 25°C cartridge temperature in a
## Abstract A capillary zone electrophoresis (CZE) method with preceding cationic transient capillary isotachophoresis (tCITP‐CZE) was developed for uncoated fused‐silica capillaries to analyze metal‐binding proteins (MBPs) of clinical relevance. UV detection was followed by mass spectrometry (MS).