Bailout coronary stenting without anticoagulation or intravascular ultrasound guidance: Acute and six-month angiographic results in a series of 120 consecutive patients

โœ Scribed by Antoniucci, David ;Valenti, Renato ;Santoro, Giovanni Maria ;Bolognese, Leonardo ;Taddeucci, Enrico ;Trapani, Maurizio ;Santini, Alberto ;Fazzini, Pier Filippo


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
40 KB
Volume
41
Category
Article
ISSN
0098-6569

No coin nor oath required. For personal study only.

โœฆ Synopsis


The purpose of this study was to evaluate the feasibility, safety, and efficacy of bailout coronary stenting without anticoagulation or intravascular ultrasound guidance in patients with acute or unequivocal threatened closure after conventional angioplasty. One hundred twenty consecutive patients were prospectively enrolled according to the following criteria: 1) acute or threatened closure after balloon angioplasty; 2) reference vessel diameter > or = 2.5 mm. All patients after stent implantation were on antiplatelet treatment with aspirin and ticlopidine. Four types of stents were used: Palmaz-Schatz (J&J), Gianturco-Roubin (Cook), Freedom (Global Therapeutics), and Microstent (AVE). Procedural results: a total of 206 stents were implanted in 134 target lesions with a stent deployment success rate of 100%; 44 target lesions were treated with multiple stent implantation; the mean luminal diameter after stenting was 3.14 +/- 0.34 mm, and the mean final percent diameter stenosis was -2 +/- 10%; the mean balloon to vessel ratio was 1.11 +/- 0.15; the mean final pressure inflation was 13.9 +/- 2.4 atm; an optimal angiographic result was achieved in 128 lesions (96%). In-hospital results: in-hospital recurrent ischemia occurred in 4 patients (3%); recurrent ischemia resulted directly in death in 1 patient, in nonfatal Q-waves infarction in 2 patients, and in emergency coronary artery surgery in 1 patient. Six-month clinical follow-up results: event free survival rate was 77%; 1 patient had non fatal infarction; the incidence of repeat revascularization procedures was 19%; there were no cardiac deaths. Angiographic follow-up results (follow-up rate 93%): the restenosis or reocclusion rate was 28%. Bailout coronary stenting without chronic anticoagulation treatment or intravascular ultrasound guidance may be considered a highly feasible and safe treatment for acute or threatened closure after failed angioplasty.


๐Ÿ“œ SIMILAR VOLUMES


Preliminary experience with stent-suppor
โœ Antoniucci, David ;Valenti, Renato ;Santoro, Giovanni Maria ;Bolognese, Leonardo ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 141 KB ๐Ÿ‘ 2 views

This report describes our preliminary experience with coronary stent-supported angioplasty in long narrowings using a long stent with an innovative design. Twenty-seven consecutive patients with target lesions G20 mm in length had a stenting procedure using the Freedom Force long coronary stent (Glo