B0 and B1-insensitive uniform T1-weighting for quantitative, first-pass myocardial perfusion magnetic resonance imaging
✍ Scribed by Daniel Kim; Alexandru Cernicanu; Leon Axel
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 299 KB
- Volume
- 54
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Myocardial perfusion can be estimated, in principle, from first‐pass MR images by converting the T~1~‐weighted signal–time curves to contrast agent concentration–time curves. Typically, T~1~ weighting is achieved by saturating the magnetization with a nonselective radiofrequency (RF) pulse prior to the imaging sequence. The accuracy of the perfusion estimate derived from the single‐point T~1~‐weighted signal depends on the initial residual longitudinal magnetization (RLM) produced by the saturation pulse. In this study we demonstrate that single‐shot, echo‐planar imaging can be used to show initial RLM resulting from incomplete saturation due to static magnetic field and RF field inhomogeneities in the heart at 1.5 T. Three saturation pulses, single, composite simple, and composite B~1~‐insensitive rotation (BIR‐4) were evaluated in phantom and cardiac experiments. The RLM image was calculated by normalizing the saturated image by a proton‐density‐weighted image. Mean RLM produced by the three saturation pulses was significantly different in noncontrast cardiac imaging (RLM~single~ = 0.108 ± 0.078; RLM~composite~ = 0.051 ± 0.052; RLM~BIR‐4~ = 0.011 ± 0.009; P < 0.001; n = 20). Using a BIR‐4 pulse to perform saturation of magnetization seems promising for improving the effectiveness and uniformity of T~1~ weighting for first‐pass perfusion imaging. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Fast imaging techniques allow monitoring of contrast medium (CM) first‐pass kinetics in a multislice mode. Employing shorter recovery times improves cardiac coverage during first‐pass conditions, but potentially flattens signal response in the myocardium. The aim of this study was there
The purpose of this study was to correlate the abnormal signal area on various magnetic resonance (MR) images to the infarct area on pathologic examination and to assess the myocardial viability on the basis of MR images. T2weighted, first-pass perfusion, and delayed gadolinium-enhanced T1-weighted
## Abstract ## Purpose To compare quantitative coronary angiography (QCA) and first‐pass perfusion magnetic resonance imaging (FPP‐MRI) in symptomatic patients with nonsevere coronary stenosis to detect a reduced coronary flow velocity reserve (CFVR). ## Materials and Methods In 35 patients, FPP