โœฆ Synopsis


Abstract

Model calibration allows reducing parameter uncertainty and, therefore, uncertainty in simulation results. In the present study, automatic model calibration with the shuffled complex evolution algorithm is demonstrated using the example of the distributed conceptual model SWATโ€G, a derivative of the Soil and Water Assessment Tool (SWAT). The special challenge in calibrating SWAT is that it describes many physical processes and therefore is highly parameterized. Moreover, as SWAT or SWATโ€G, respectively, is a distributed model, the parameters may take on different values in different spatial subunits of a catchment model. A strategy of imposing constraints on the parameters to limit the number of independently calibrated values is outlined and applied to the model of a mesoscale low mountain range catchment. Copyright ยฉ 2005 John Wiley & Sons, Ltd.


๐Ÿ“œ SIMILAR VOLUMES


Development of an automatic calibration
โœ Xingnan Zhang; Gรถran Lindstrรถm ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 223 KB ๐Ÿ‘ 1 views

An automatic calibration scheme for the HBV model (ACSH) was developed. The ACSH was based on the physical signiยฎcance of the model parameters and structure. The inference of hydrologists in the manual calibration was adopted as the guideline. A slight modiยฎcation of the model structure of the soil

Automatic calibration in capillary elect
โœ Lourdes Arce; Peter Hinsmann; Milko Novic; Angel Rรญos; Miguel Valcรกrcel ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 183 KB ๐Ÿ‘ 1 views

A direct, completely automated calibration procedure in capillary electrophoresis (CE) is presented. The manual calibration operations involved in analytical methods, such as external calibration, standard addition, and internal standard, were accomplished with a continuous flow system (CFS) coupled

4724378 Calibrated automatic test system
โœ DonaldF Murray; StevenK Sullivan ๐Ÿ“‚ Article ๐Ÿ“… 1988 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 85 KB
Automatically controlled low temperature
โœ H. Demattio; K.D. Rusch; M. SรผรŸer ๐Ÿ“‚ Article ๐Ÿ“… 1994 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 278 KB

The present calibration facility has been modified during the last years. The existing measurement components such as digital multimeter, multiplexers, current sources and control system for temperature controlling have been replaced. All the necessary modes of operation are now controlled by a pers