Autologous bone versus calcium-phosphate ceramics in treatment of experimental bone defects
✍ Scribed by Bloemers, Frank W. ;Blokhuis, Taco J. ;Patka, Peter ;Bakker, Fred C. ;Wippermann, Burkhard W. ;Haarman, Henk J.Th.M.
- Publisher
- John Wiley and Sons
- Year
- 2003
- Tongue
- English
- Weight
- 162 KB
- Volume
- 66B
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Autologous bone grafting is currently considered the treatment of choice for correction of large bone defects. However, to avoid morbidity associated with autologous bone harvesting many artificial bone‐substitute materials have been developed over the years. A new generation of resorbable materials is emerging, with promising results so far. In order to investigate the possibility to use one of these new materials as an alternative with better results than hydroxyapatite, an experimental study was performed. A new resorbable calcium phosphate particles and paste forms, the latter of which hardens in situ after application. In 28 sheep, a 3‐cm segmental tibial defect was made and intramedullary fixed by an interlocking nail. Twelve weeks after defect filling, radiological, biomechanical, and histological examinations were performed. Mean radiographic and biomechanical tests results were compared with the Mann‐Whitney test. Significance was set at p < 0.05. Radiographically, the resorbable paste group performed better than all other groups. Biomechanical investigations showed a higher torsional stiffness (p = 0.049) for the resorbable calcium‐phosphate paste group in comparison with autologous bone. On histological examination, no adverse effects were observed in the calcium‐phosphate groups. Resorbtion by osteoclasts was seen in the resorbable implants. In conclusion, the current study shows an advantageous radiological and mechanical outcome for resorbable calcium phosphates. This indicates that these new materials might be a potential alternative for autologous bone grafting in humans. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 66B: 526–531, 2003
📜 SIMILAR VOLUMES
In order to understand the influence of the implantation site on bone biomaterial evaluation, we implanted cylinders of HA and beta-TCP ceramics in the femoral diaphysis and condyle of rabbits. After 3, 8, 12, and 24 weeks of implantation, histological investigation and histomorphometry were perform
## Abstract We investigated histological and compressive properties of a calcium phosphate bone cement (BoneSource® (CPC); Stryker Orthopaedics, Mahwah, New Jersey) plus carboxymethyl cellulose (CMC) using a sheep vertebral bone void model. Bone voids were surgically created in L3 and L5 in each of
## Abstract Two glass ceramics in the CaOP~2~O~5~MgO system with the incorporation of K~2~O or TiO~2~ oxides were prepared with the goal of using them as potential bone graft substitutes. The incorporation of TiO~2~ and K~2~O led to the preparation of specific crystalline phases in the structure
## Abstract This study investigated the effects of rabbit autologous platelet lysates (APL) on the performance of fillers consisting of calcium carbonate ceramic particles (CP) pertinent to new bone formation and repair. Critical‐size defects in rabbit femurs and calvaria were filled with CP alone,
The purpose of this study was to evaluate the therapeutic efficacy of a new calcium phosphate (CaP)-based formulation in improving the bone mineral deficiency in ovariectomized (OVX) rats. The ions release experiments for CaP preparations (G2: 0.46% Mg, 5.78% Zn, and 2.5% F; G3:3.1% Mg, 0.03% Zn, an