𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Assessment of the exposure to WLAN frequencies of a head model with a cochlear implant

✍ Scribed by Marta Parazzini; Federica Sibella; Alessia Paglialonga; Paolo Ravazzani


Publisher
John Wiley and Sons
Year
2010
Tongue
English
Weight
234 KB
Volume
31
Category
Article
ISSN
0197-8462

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

In the last few years, significant developments have taken place in the field of Wireless Local Area Networks (WLAN), and the popularity of portable devices supporting Wireless Fidelity (Wi‐Fi) is continuously growing. At the same time, the number of Active Implanted Medical Devices (AIMD) being placed in patients is widely increasing and among them, cochlear implants (CI) are becoming a common aid. The goal of this study is to investigate the effect on the electromagnetic field distribution and the specific absorption rate (SAR) due to the presence of a CI in a head model during far‐field exposure to Wi‐Fi frequencies. The head model was obtained by image segmentation, the implant was modelled as a geometric structure, and the exposure sources were modelled as a uniform plane wave (power density = 10 W/m^2^) at 2.4, 5.2 and 5.8 GHz. Vertical and horizontal polarizations were simulated. Conditions with and without CI were compared. The findings of that are: (1) local differences in the field distribution close to the CI, comparing the head models with or without the CI; (2) higher field strength and point SAR value in the cochlear region very close to the CI; (3) negligible differences in the field strength and point SAR value in the cochlear region far from the CI; (4) negligible variations in the average SAR values in the cochlea and head due to the presence of the CI. The results of this study conclude that insertion of a CI brings moderate localized differences in the E, H and point SAR distribution when evaluated close to the electrode array in the cochlea, while negligible differences are found in the average SAR values both in the cochlea and head, independent of frequency and wave polarization. Bioelectromagnetics 31:546–555, 2010. Β© 2010 Wiley‐Liss, Inc.


πŸ“œ SIMILAR VOLUMES


A fuzzy mathematical programming approac
✍ T. LeΓ³n; V. Liern; J.L. Ruiz; I. Sirvent πŸ“‚ Article πŸ“… 2003 πŸ› Elsevier Science 🌐 English βš– 255 KB

In many real applications, the data of production processes cannot be precisely measured. This is particularly worrying when assessing e ciency with frontier-type models, such as data envelopment analysis (DEA) models, since they are very sensitive to possible data errors. For this reason, the possi

Safety of, and biological and functional
✍ Carl A. Kirker-Head; David C. Van Sickle; Steve W. Ek; John C. McCool πŸ“‚ Article πŸ“… 2006 πŸ› Elsevier Science 🌐 English βš– 600 KB

## Abstract Focal full‐thickness cartilage lesions of the human medial femoral condyle (MFC) can cause pain and functional impairment. Affected middle‐aged patients respond unpredictably to existing treatments and knee arthroplasty may be required, prompting risk of revision. This study assesses th