𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Assessment of spontaneous coronary artery dissection by intravascular ultrasound in a patient with unstable angina

✍ Scribed by Kearney, Peter ;Erbel, Raimund ;Ge, Junbo ;Zamorano, Jose ;Koch, Lothar ;Görge, Gunter ;Meyer, Jurgen


Publisher
John Wiley and Sons
Year
1994
Tongue
English
Weight
433 KB
Volume
32
Category
Article
ISSN
0098-6569

No coin nor oath required. For personal study only.

✦ Synopsis


We describe a case of spontaneous coronary artery dissection that gave rise to post infarction unstable angina. An ambiguous angiographic appearance was shown by intracoronary ultrasound to arise from an extensive coronary dissection. The dissection membrane separating true and false lumina and features to suggest sluggish flow and early thrombosis in the false lumen were observed. No increase in lumen calibre was evident on ultrasound afler PTCA (probably a consequence of the relatively large ultrasound catheter blank), but coronary flow reserve measured with intracoronary Doppler did Improve and the patient remained stable and free of angina following the procedure.