𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Assessment of mitral bioprostheses using cardiovascular magnetic resonance

✍ Scribed by Florian von Knobelsdorff-Brenkenhoff; André Rudolph; Ralf Wassmuth; Jeanette Schulz-Menger


Publisher
BioMed Central
Year
2010
Tongue
English
Weight
959 KB
Volume
12
Category
Article
ISSN
1097-6647

No coin nor oath required. For personal study only.

✦ Synopsis


Background:

The orifice area of mitral bioprostheses provides important information regarding their hemodynamic performance. it is usually calculated by transthoracic echocardiography (tte), however, accurate and reproducible determination may be challenging. cardiovascular magnetic resonance (cmr) has been proven as an accurate alternative for assessing aortic bioprostheses. however, whether cmr can be similarly applied for bioprostheses in the mitral position, particularly in the presence of frequently coincident arrhythmias, is unclear. the aim of the study is to test the feasibility of cmr to evaluate the orifice area of mitral bioprostheses.

Methods:

Cmr planimetry was performed in 18 consecutive patients with mitral bioprostheses (n = 13 hancock(r), n = 4 labcore(r), n = 1 perimount(r); mean time since implantation 4.5 +/- 3.9 years) in an imaging plane perpendicular to the transprosthetic flow using steady-state free-precession cine imaging under breath-hold conditions on a 1.5t mr system. cmr results were compared with pressure half-time derived orifice areas obtained by tte.

Results:

Six subjects were in sinus rhythm, 11 in atrial fibrillation, and 1 exhibited frequent ventricular extrasystoles. cmr image quality was rated as good in 10, moderate in 6, and significantly impaired in 2 subjects. in one prosthetic type (perimount(r)), strong stent artifacts occurred. orifice areas by cmr (mean 2.1 +/- 0.3 cm2) and tte (mean 2.1 +/- 0.3 cm2) correlated significantly (r = 0.94; p < 0.001). bland-altman analysis showed a 95% confidence interval from -0.16 to 0.28 cm2 (mean difference 0.06 +/- 0.11 cm2; range -0.1 to 0.3 cm2). intra- and inter-observer variabilities of cmr planimetry were 4.5 +/- 2.9% and 7.9 +/- 5.2%.

Conclusions:

The assessment of mitral bioprostheses using cmr is feasible even in those with arrhythmias, providing orifice areas with close agreement to echocardiography and low observer dependency. larger samples with a greater variety of prosthetic types and more cases of prosthetic dysfunction are required to confirm these preliminary results.


📜 SIMILAR VOLUMES


Assessment of significant coronary arter
✍ Jodi Harker; Judy Luu; James Hare; Dominik P Guensch; Matthias G Friedrich 📂 Article 📅 2012 🏛 BioMed Central 🌐 English ⚖ 102 KB

Oxygenation-sensitive CMR at 1.5T can be used to identify functionally significant coronary artery stenosis, by demonstrating a blunted response to adenosine induced hyperaemia. Image quality remains a limitation.

Mitral valve abnormalities identified by
✍ Martin S Maron; Caitlin Harrigan; Iacopo Olivotto; Evan Appelbaum; C Michael Gib 📂 Article 📅 2010 🏛 BioMed Central 🌐 English ⚖ 104 KB

Publish with Bio Med Central and every scientist can read your work free of charge "BioMed Central will be the most significant development for disseminating the results of biomedical researc h in our lifetime.