𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Assessment of exposure to intermediate frequency electric fields and contact currents from a plasma ball

✍ Scribed by Tommi Alanko; Lauri Puranen; Maila Hietanen


Publisher
John Wiley and Sons
Year
2011
Tongue
English
Weight
146 KB
Volume
32
Category
Article
ISSN
0197-8462

No coin nor oath required. For personal study only.

✦ Synopsis


While electric fields at intermediate frequencies are not widely utilized for industrial technologies, surprisingly, certain toys emit the highest electric fields found in our living environment. These toys, plasma balls, are devices that use high voltage to create ionized light discharges. In this study, we assessed exposure to electric fields and contact/induced current from a recreational plasma ball device. The electric field strength was measured as a function of distance from the device, and the contact/induced current was measured with a current clamp in different exposure situations with point or grasping contact. The characteristic spectra of the electric field and contact current were measured, and both the multiple frequency rule and weighting of the spectra were applied according to the International Commission on Non-Ionizing Radiation Protection (ICNIRP) 1998 and 2010 guidelines. The results indicate that the recommended reference levels for the general public are exceeded at distances <1.2 m, and that the contact currents in the hand may be twice higher than recommended by the general public guidelines.