𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Assessment of bolus injection protocol with appropriate concentration for quantitative assessment of pulmonary perfusion by dynamic contrast-enhanced MR imaging

✍ Scribed by Yoshiharu Ohno; Kenya Murase; Takanori Higashino; Munenobu Nogami; Hisanobu Koyama; Daisuke Takenaka; Hideaki Kawamitu; Sumiaki Matsumoto; Hiroto Hatabu; Kazuro Sugimura


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
580 KB
Volume
25
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To determine the appropriate concentration for quantitative assessment of dynamic contrast‐enhanced pulmonary MR imaging.

Materials and Methods

A total of 40 consecutive patients with small bronchioalveolar carcinoma underwent perfusion single‐photon emission tomography (SPECT) and three‐dimensional (3D) dynamic MR imaging with a 3D radiofrequency spoiled gradient‐echo sequence. In each patient, 5 mL of contrast media with 0.1, 0.3, and 0.5 mmol/mL were administered at a rate of 5 mL/second. All patients were divided into two groups (<70 kg and ≥70 kg) for assessment of appropriate concentration to quantitatively assess regional perfusion parameter in routine clinical practice. Pulmonary blood flow (PBF) in each protocol was calculated from a signal intensity (SI)–time course curve. Differences and limits of agreement of PBF between dynamic MR imaging (PBF~MR~) using three different concentrations and perfusion SPECT (PBF~SPECT~) were statistically compared in both patient groups.

Results

PBF~MR~ using 0.3 mmol/mL in the <70‐kg group and 0.5 mmol/mL in the ≥70‐kg group showed no significant difference compared with PBF~SPECT~ (P > 0.05). Limits of agreements in 0.3 mmol/mL in the <70‐kg group and 0.5 mmol/mL in the ≥70‐kg group were smaller than those of the other concentrations and small enough for clinical purposes.

Conclusion

Appropriate concentrations provide accurate and reproducible assessments of regional pulmonary perfusion parameters on 3D dynamic MR perfusion imaging. We suggest using 5 mL of contrast media with 0.3 mmol/mL for patients weighing less than 70 kg and 0.5 mmol/mL for patients weighing 70 kg or more. J. Magn. Reson. Imaging 2007. © 2006 Wiley‐Liss, Inc.