## Abstract Recent efforts in our laboratory have focused on developing methods for immobilizing bioactive peptides to low cell‐adhesive dextran monolayer coatings and promoting biospecific cell adhesion for biomaterial implant applications. In the current study, this dextran‐based bioactive coatin
Assessment of bioactivity for orthopedic coatings in a gap-healing model
✍ Scribed by Sakkers, R. J. B. ;Dalmeyer, R. A. J. ;Brand, R. ;Rozing, P. M. ;van Blitterswijk, C. A.
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 313 KB
- Volume
- 36
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
✦ Synopsis
In order to study bone growth conducting capacities of new biomaterials under standardized conditions, a goat model was developed based on a canine model by Soballe. Titanium alloy implants with and without a hydroxyapatite coating were used as positive and negative controls, and these were implanted with a circumferential gap of one millimeter in the spongious bone of the knee condyles of two groups of four goats. These goats were sacrificed at 6 and 25 weeks. A second experiment was done on two groups of four goats with the same type of titanium alloy and hydroxyapatite-coated implants as controls and with Polyactive 55-45 coated titanium alloy implants for testing. These goats were sacrificed at 9 and 25 weeks, respectively. Qualitative and quantitative differences in gap healing were evaluated through light microscopy, and initiation and direction of bone apposition were determined with fluorescence microscopy. Apposition of bone was seen directly on all hydroxyapatite surfaces and on some of the noncoated titanium alloy surfaces. The difference between the percentage of bone growth on the titanium alloy implants and the hydroxyapatite-coated implants appeared to be divergent in time: the bone growth on the noncoated implants declined after 9 weeks in contrast to the steady increase of bone growth on the hydroxyapatite-coated implants towards the 25 week follow-up time (p = 0.02). No significant difference was found between the first and the second experiment: apposition of bone on the implants differed only 6.6% on a scale of 0% to 100%. Only scarce bone growth was seen on the polyactive-coated implants in this model. The newly tested Polyactive 55-45 coating apparently needs initial bone contact for bone-bonding and therefore showed hardly any direct bone formation on its surface. The clear differences in the reaction of bone to the coated and noncoated implants in this goat study and the reproducibility of these reactions of bone to the different controls indicate the sensitivity of the currently used animal model and its suitability for use as a bioactivity assay.
📜 SIMILAR VOLUMES
## Abstract The primary purpose of this study was to test the hypothesis that an in vivo model of posterolateral knee instability could be created in the rabbit and to develop a natural history model in animals. The biomechanical and gross features of the rabbit knee 12 weeks after rupture of the
## Abstract Primary cementless joint replacement depends partly on the ability of bone to heal into those areas of an inserted implant where a gap to surrounding bone initially exists. A new bone preparation technique, compaction, has enhanced gap‐healing around grit‐blasted implants without osteoc
## Abstract Recent advances in the isolation, expansion, and characterization of human mesenchymal stem cells (hMSCs) have raised the possibility of using them in cell therapies and tissue engineering for bone reconstruction. hMSCs, isolated from the bone marrow of eight normal adult patients, were
## Abstract We aimed to establish a novel approach with 3D high frequency power Doppler ultrasonography (3D‐HF‐PDU) to assess microvasculature at the fracture site in rat femurs by comparing with microCT‐based microangiography. Twenty‐four 9‐month‐old ovariectomized (OVX) osteoporotic rats and age‐
## Abstract An important category of self‐healing materials relies on the release of a healing agent from a capsule upon the occurrence of damage to the material. Visualization of the release of the healing agent is difficult to accomplish. Here we show that a profluorophore can successfully be use