APPLICATION OF THE PSTAR METHOD TO A MASSIVE TEST CELL FOR THERMAL PERFORMANCE EVALUATION

โœ Scribed by W. G. Chun; M. S. Jeon; H. K. Yoon; H. S. Jeon; P. C. Auh


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
303 KB
Volume
21
Category
Article
ISSN
0363-907X

No coin nor oath required. For personal study only.

โœฆ Synopsis


This paper studies the thermal performance of a small thermally massive test cell built by the Korea Institute of Energy Research (KIER) located in Daejeon, Korea. The cell is 3 m wide, 3โ€ข6 m long and 2โ€ข6 m high. It is built mainly with concrete and cement bricks. A partition wall divides the interior of the building (cell) into two zones: a living and a buffer zone. Space heating of the building is provided by coils carrying hot water imbedded in the massive floor. This case study was of special interest because the KIER test cell is significantly more massive than those previously tested using the same methodology by the National Renewable Energy Laboratory (NREL) in the United States. A series of short-term tests were conducted to evaluate the major heat flow terms which largely influence building performance. The test procedure and data analysis were carried out according to the PSTAR method developed by the NREL. Each test period was three days during which the building was unoccupied. The data measured with eight channels were used to renormalize an audit based simulation model of the building. Results show close agreements between the measured and renormalized values reflecting the effects of heavy thermal mass, whereas the simulation results from the audit description of the test cell deviate considerably. A long-term extrapolation has also been made from the weather data of Seoul TMY (Typical Meteorological Year) for the calculation of monthly heating and cooling loads. 1997


๐Ÿ“œ SIMILAR VOLUMES


Performance evaluation of the Quick Test
โœ Dong Chen; David Shattuck; Mark Hines; Joan McLean ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons โš– 115 KB ๐Ÿ‘ 2 views

A novel colorimetric-based field test kit, the Quick Testเฎพ, has been developed by Envirol Inc. (North Logan, UT), for the quantitation of pentachlorophenol (PCP) in soil. The Quick Test differs from commercially available immunoassay field tests for PCP in that it is based on a photochemically induc

A new method for quantitative determinat
โœ Dallies, Nathalie; Franรงois, Jean; Paquet, Veronique ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 148 KB ๐Ÿ‘ 1 views

A reliable acid hydrolysis method for quantitative determination of the proportion of -glucan, mannan and chitin in Saccharomyces cerevisiae cell wall is reported together with a simple extraction procedure to quantify within a standard error of less than 2% the proportion of the wall per gram of ce

A high-performance liquid chromatographi
โœ Ke Li; Xin Zhang; Yi-sheng Yuan; Fei-lang Zhao ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 55 KB ๐Ÿ‘ 1 views

A simple and sensitive reversed-phase liquid chromatographic method has been developed and validated for the analysis of nicardipine in human plasma and the study of the pharmacokinetics of the drug in human body. Nicardipine and nimodipine (internal standard) in plasma were extracted with hexane-bu