An NMR imaging technique sensitive to slow flow (approximately 1 mm/s) using a conventional imaging gradient strength (0.025 mT/cm) is described. Two projections with different spatial magnetic periodicity (determined by the SSFP pulse interval), and thus with different flow sensitivities, are subtr
Application of missing pulse steady state free precession to the study of renal microcirculation
✍ Scribed by M. E. Stromski; H. R. Brady; S. R. Gullans; S. Patz
- Publisher
- John Wiley and Sons
- Year
- 1991
- Tongue
- English
- Weight
- 819 KB
- Volume
- 20
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Missing pulse steady state free precession (MP‐SSFP), an extension of steady state free precession (SSFP), was evaluated for its ability to measure slow fluid flows. In experiments using flow phantoms, the MP‐SSFP signal was sensitive to fluid velocities in the millimeters per second range. Isolated perfused rabbit kidneys were then used to determine if MP‐SSFP could measure perfusion in a biological tissue. The signal intensities in the different anatomical regions of the kidney were observed to be related to the total flow to the organ. Furthermore, increasing the flow sensitivity of the pulse sequence by increasing the gradient strength resulted in decreases in the image signal intensity. The MP‐SSFP signal was more sensitive to flow in the medulla than in the cortex. This can be related to slow flow sensitivity of MP‐SSFP and the known differences in velocity profiles between these two regions. These results suggest that MP‐SSFP may be a powerful tool for the noninvasive measurement of slow fluid flows in different regions of the kidney. © 1991 Academic Press, Inc.
📜 SIMILAR VOLUMES
## Abstract The transient phase of short–TR steady‐state free precession (SSFP) sequences exhibits an often striking complexity and is not only important for nonequilibrium applications (e.g., rapid __T__~1~–measurements), but can also cause severe artifacts in conventional imaging. In both cases,
When calculating the average course of the decay of RF-spoiled SSFP sequences (red curves in Fig. 9c andd), the integration contour not only enclosed the singularities on the real positive axis (red line in Fig. 9b) but, accidentally, also the two adjacent complex conjugate end points of the green c
## Abstract ## Purpose To evaluate the potential of fully‐balanced steady‐state free‐precession (SSFP) sequences in in vivo high‐resolution (HR) MRI of trabecular bone at field strengths of 1.5 and 3 T by simulation and experimental methods. ## Materials and Methods Using simulation studies, ref