Application of high performance liquid chromatography/tandem mass spectrometry in the environmental and biological monitoring of health care personnel occupationally exposed to cyclophosphamide and ifosfamide

✍ Scribed by Claudio Minoia; Roberta Turci; Cristina Sottani; Angelo Schiavi; Luigi Perbellini; Sergio Angeleri; Francesco Draicchio; Pietro Apostoli


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
188 KB
Volume
12
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

✦ Synopsis


Twenty four workers (10 involved in the preparation and 14 in administration) exposed to cyclophosphamide (CP) and ifosfamide (IF) in two Italian hospitals were monitored. The extent of exposure was assessed by the analysis of air samples, wipe samples, pads and gloves. Urinary excretion at the beginning and at the end of the work shift was also measured by liquid-liquid extraction and analysis by high performance liquid chromatography/tandem mass spectrometry. Three out of 24 air samples were positive for CP or IF. In wipe samples, CP concentrations ranging from 0.001 to 82.4 mg/dm 2 in Hospital A (32 samples) and from 0.2 to 383.3 mg/dm 2 in Hospital B (17 samples), were found. IF concentrations varied from 0.001 to 90.9 mg/dm 2 in Hospital A and from 0.01 to 141.5 mg/dm 2 in Hospital B. Pads (from 11 to 13 for each operator) were contaminated with CP and IF especially on arms, legs and chest. The use of a plastic-backed liner on the working tray in the laminar flow hoods was demonstrated to compromise the containment properties of the hood. Urine samples were positive for CP in 50% of the workers (range: 0.1-2.1 mg/L), whereas IF was detected in 2 subjects only (range: 0.1-0.8 mg/L). The results of this investigation demonstrate that vertical laminar airflow hoods, when incorrectly used, might represent a source of contamination and that higher risk may depend on lack of educational programmes and observance of preventive guidelines.