𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Application of DENSE-MR-elastography to the human heart

✍ Scribed by Benjamin Robert; Ralph Sinkus; Jean-Luc Gennisson; Mathias Fink


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
547 KB
Volume
62
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Typically, MR‐elastography (MRE) encodes the propagation of monochromatic acoustic waves in the MR‐phase images via sinusoidal gradients characterized by a detection frequency equal to the frequency of the mechanical vibration. Therefore, the echo time of a conventional MRE sequence is typically longer than the vibration period which is critical for heart tissue exhibiting a short T~2~. Thus, fast acquisition techniques like the so‐called fractional encoding of harmonic motions were developed for cardiac applications. However, fractional encoding of harmonic motions is limited since it is two orders of magnitude less sensitive to motion than conventional MRE sequences for low‐frequency vibrations. Here, a new sequence is derived from the so‐called displacement encoding with stimulated echoes (DENSE) sequence. This sequence is more sensitive to displacement than fractional encoding of harmonic motions, and its spectral specificity is equivalent to conventional MRE sequences. The theoretical spectral properties of this new motion‐encoding technique are validated in a phantom and excised pork heart specimen. An excellent agreement is found for the measured displacement fields using classic MRE and displacement encoding with stimulated echoes MRE (8% maximum difference). In addition, initial in vivo results on a healthy volunteer clearly show propagating shear waves at 50 Hz. Thus, displacement encoding with stimulated echoes MRE is a promising technique for motion encoding within short T~2~* materials. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


High-Resolution Strain Analysis of the H
✍ Anthony H. Aletras; Robert S. Balaban; Han Wen 📂 Article 📅 1999 🏛 Elsevier Science 🌐 English ⚖ 892 KB

Single breath-hold displacement data from the human heart were acquired with fast-DENSE (fast displacement encoding with stimulated echoes) during systolic contraction at 2.5 ؋ 2.5 mm in-plane resolution. Encoding strengths of 0.86 -1.60 mm/ were utilized in order to extend the dynamic range of the

Equation of State of Dense Plasma Mixtur
✍ J.C. Pain; G. Dejonghe; T. Blenski 📂 Article 📅 2012 🏛 John Wiley and Sons 🌐 English ⚖ 147 KB 👁 2 views

## Abstract We present a self‐consistent approach to the modeling of dense plasma mixtures in local thermodynamic equi‐librium. In each electron configuration the nucleus is totally screened by electrons in a Wigner‐Seitz sphere (ion‐sphere model). Bound and free electrons are treated quantum‐mecha

Fast, interactive algorithm for segmenta
✍ Jin Zhao Wang; David A. Turner; Mariano D. Chutuape 📂 Article 📅 1992 🏛 John Wiley and Sons 🌐 English ⚖ 756 KB

## Abstract Magnetic resonance (MR) cine images of the beating heart have excellent spatial and temporal resolution. Extracting the boundaries of the heart from MR images for volumetric measurements is of considerable interest; however, since the number of images involved is large, tracing the boun