## Abstract A sensitive and efficient solid‐phase microextraction method, based on liquid chromatography and UV–Vis detection, was developed and validated as an alternative method for sample screening prior to LC‐MS analysis. It enables the simultaneous determination of ten pesticides in mango frui
Application of continual injection liquid-phase microextraction method coupled with liquid chromatography to the analysis of organophosphorus pesticides
✍ Scribed by Yanuardi Raharjo; Mohd Marsin Sanagi; Wan Aini Wan Ibrahim; Ahmedy Abu Naim; Hassan Y. Aboul-Enein
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 906 KB
- Volume
- 32
- Category
- Article
- ISSN
- 1615-9306
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A liquid‐phase microextraction coupled with LC method has been developed for the determination of organophosphorus pesticides (methidation, quinalphos and profenofos) in drinking water samples. In this method, a small amount (3 μL) of isooctane as the acceptor phase was introduced continually to fill‐up the channel of a 1.5 cm polypropylene hollow fiber using a microsyringe while the hollow fiber was immersed in an aqueous donor solution. A portion of the acceptor phase (ca. 0.4 μL) was first introduced into the hollow fiber and additional amounts (ca. 0.2 μL) of the acceptor phase were introduced to replenish at intervals of 3 min until set end of extraction (40 min). After extraction, the acceptor phase was withdrawn and transferred into a 2 mL vial for a drying step prior to injection into a LC system. Parameters that affect the extraction efficiency were studied including the organic solvent, length of fiber, volume of acceptor and donor phase, stirring rate, extraction time, and effect of salting out. The proposed method provided good enrichment factors of up to 189.50, with RSD ranging from 0.10 to 0.29%, analyte recoveries of over 79.80% and good linearity ranging from 10.0 to 1.25 mg/L. The LOD ranged from 2.86 to 82.66 μg/L. This method was applied successfully to the determination of organophosphorus pesticides in selected drinking water samples.
📜 SIMILAR VOLUMES
## Dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography-diode array detection for the determination of N-methyl carbamate pesticides in vegetables This paper described a simple, rapid and efficient method for the determination of N-methyl carbamate pesticide
## Abstract A novel interface that allows normal‐phase liquid chromatography to be coupled with electrospray ionization (ESI) is reported. A make‐up solution of 60 mM ammonium acetate in methanol, infused at a 5 µl min^−1^ flow‐rate at the tip of the electrospray probe, provides a sheath liquid whi
## Abstract Solid‐phase extraction combined with dispersive liquid–liquid microextraction (SPE‐DLLME) was applied for the extraction of six organophosphorous pesticides (OPPs) in water samples. The analytes considered in this study were determined by gas chromatography with mass spectrometry and in
Reversed-phase HPLC method by direct plasma injection has been developed for the analysis of major tryptophan metabolites (both metabohtes in kynurenine pathways and in indole pathways). Two columns were used: one was a short precolumn of protein-coated octadecylsilane (ODS) for deproteinization and