𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Apparent diffusion tensor measurements in myelin-deficient rat spinal cords

✍ Scribed by V. Gulani; A.G. Webb; I.D. Duncan; P.C. Lauterbur


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
197 KB
Volume
45
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


The apparent diffusion tensor (ADT) was measured in excised and fixed spinal cords from myelin-deficient (md) rats and age-matched controls. These data were used to obtain the principal diffusivities of the ADT, and also the scalar invariant parameters _D (averaged principal diffusivity) and A(sigma) (anisotropy index) for four white matter and two gray matter regions. The results for white matter regions showed that the principal diffusivities were significantly higher for md animals, and while the _D was increased in tissue from md animals, the A(sigma) was found to be decreased. Grey matter _D was measured to be between those of white matter from control and md animals, and the A(sigma) was much smaller than that of white matter from both sets of animals, indicating that diffusion in md white matter is more anisotropic than in gray matter. The results show that while myelination is not a prerequisite for diffusion anisotropy, it does influence the magnitude of the observed anisotropy. Magn Reson Med 45:191-195, 2001.


πŸ“œ SIMILAR VOLUMES


High-resolution myelin water measurement
✍ Piotr Kozlowski; Jie Liu; Andrew C. Yung; Wolfram Tetzlaff πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 349 KB

## Abstract Multiecho imaging data were acquired at 7T from control and injured (dorsal column transection) rat spinal cords ex vivo with in‐plane resolution of 61, 78, and 100 ΞΌm, and from a control rat spinal cord in vivo with in‐plane resolution of 117 ΞΌm. The myelin water maps were calculated u

Diffusion tensor imaging of in vivo and
✍ Saaussan Madi; Khader M. Hasan; Ponnada A. Narayana πŸ“‚ Article πŸ“… 2004 πŸ› John Wiley and Sons 🌐 English βš– 318 KB

## Abstract Regional values of fractional anisotropy (FA) and mean diffusivity (__D__~av~) of in vivo and excised rat spinal cords were measured using an iscosahedral encoding scheme that is based on 21 uniformly distributed and alternating gradient directions with an echo planar imaging (EPI) read