To evaluate the efficacy of the more flexible Cordis stent, a prospective angiographic follow-up study was performed. Implantation of the Cordis stent was attempted in 99 consecutive patients with 103 native coronary lesions from January 1994 to July 1995. Clinical success, defined as final diameter
Angiographic follow-up and clinical experience with the flexible tantalum cordis stent
โ Scribed by Watson, Paul S. ;Ponde, Chandrashekhar K. ;Aroney, Constantine N. ;Cameron, James ;Cannon, Adam ;Dooris, Mark ;Garrahy, Paul J. ;McEniery, Paul T. ;Bett, John H. N.
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 141 KB
- Volume
- 43
- Category
- Article
- ISSN
- 0098-6569
No coin nor oath required. For personal study only.
โฆ Synopsis
The Cordis stent is a flexible, highly radioopaque intracoronary stent engineered from a single Tantalum filament folded into a sinusoidal helical coil. It is premounted on a semicompliant balloon expandable stent delivery system. From September 1995-March 1996, 147 Cordis stents were deployed in 105 patients (aged 58 ุ 12 yr, 71% male). Clinical indications for stenting were unstable angina in 59 (55%), stable angina in 41 (38%), and acute myocardial infarction in 7 (7%). The target vessel was the right coronary artery in 45%, the left anterior descending in 31%, and the circumflex artery in 22%. One stent was deployed in a vein graft, and one stent was deployed in a left internal mammary artery graft. Stent deployment was achieved in all but one patient. Acute in-stent thrombosis occurred in 3 patients (2.9%). Two of these patients required urgent coronary artery bypass surgery. Subacute stent thrombosis occurred in 2 patients (1.9%). Minimum lumen diameter increased from 0.70 ุ 0.41 mm to 3.50 ุ 0.60 mm following stent placement. All patients received aspirin. Eighty-one patients (77%) received ticlopidine, and 4 patients (4%) received warfarin therapy. The mean hospital stay was 3.4 ุ 2.3 days. Six-month follow-up angiography was performed on 50 out of 55 eligible patients at one of the two institutions involved in this study. Computer-assisted quantitative coronary angiography defined a restenosis rate of 26%. Repeat revascularization was required in 8 patients (14.5%) at 6-mo follow-up.
The Tantalum Cordis intracoronary stent is an effective and safe means of treating coronary lesions, even in patients with unstable ischemic syndromes. Acute and subacute rates of in-stent thrombosis were acceptable, and the long-term angiographic restenosis rates and need for repeat revascularization were favorable. Cathet.
๐ SIMILAR VOLUMES
The EBI (BARD-XT, C.R. Bard, Murray Hill, NJ) stent is a new radiopaque balloon expandable coronary stent with high resistance to external radial forces. It does not shorten significantly with expansion and allows stent implantation in bifurcation lesions. A total of 28 EBI stents were implanted in
The objective of this study was to assess the angiographic and clinical outcome of patients with coronary in-stent restenosis treated with balloon angioplasty with provisional stenting. The study included 375 consecutive patients with in-stent restenosis managed with balloon angioplasty alone or com
A 45-year-old white male, 35-year status postrepair of coarctation of the aorta, presented with symptomatic recoarctation of the aorta. He was treated successfully by implantation of a single Palmaz stent. The pressure gradient was abolished with complete resolution of symptoms. Seven months postste
Optimal stent expansion is considered imperative today in order to prevent subacute stent thrombosis and allows us to minimize antithrombotic therapy. The short-term angiographic and long-term clinical follow-up of a patient with a suboptimally expanded vein graft balloon expandable stent is present