Hollow fiber membrane modules have been employed for heat and moisture recovery from ventilation air. There are several benefits with this structure. The contact area is large. The resulting NTU (Number of Transfer Units) is high, which implicates a high performance. In this research, the governing
โฆ LIBER โฆ
Analytical solutions for rotary matrix wire screen heat exchangers
โ Scribed by W.H.T. Loh
- Publisher
- Elsevier Science
- Year
- 1961
- Tongue
- English
- Weight
- 577 KB
- Volume
- 272
- Category
- Article
- ISSN
- 0016-0032
No coin nor oath required. For personal study only.
โฆ Synopsis
Instead of the partial differential equation commonly used for rotary matrix heat exchangers, an ordinary differential equation is developed for a single stage rotary wire screen heat exchanger. This equation results in an exact solution for temperature effectiveness. The solution for a multi-screen system is then developed by an energy balance of each individual single screen. Based on analytical solutions obtained here, design charts for rotary multilayer wire screen heat exchangers are presented.