PAN1 6lms of thicknesses from 0.06 to 7~ were investigated by the potentiostatic pulse method and EIS. The 6hns behaved very similar in respect to both methods over the whole range of thicknesses. The oxidii fIhn can be described as a battery electrode with a specific capacity as high as 130Fcmm3. T
Analysis of the use of “IR” compensators in potentiostatic investigations
✍ Scribed by A. Bewick
- Publisher
- Elsevier Science
- Year
- 1968
- Tongue
- English
- Weight
- 337 KB
- Volume
- 13
- Category
- Article
- ISSN
- 0013-4686
No coin nor oath required. For personal study only.
✦ Synopsis
The effect of an "IR" compensator on the performance of a potentiostatic feedback system is analysed. It is shown that severe overcompensation can readily be produced, and that the attempted remedy can be worse than the original malady.
R&u&-Analyse de l'effet d'un compensateur "IR" sur la performance d'un systeme potentiostatique "feedback".
On montre qu'une surcompensation importance peut facilement se r&liser et que le rem&de pourrait ainsi &tre pire que le mal.
Znsanunenfassnng-Es wird eine Analyse des Einlhrsses eines IR-Kompensators auf das Verhalten des rtickgekoppelten
Systems eines Potentiostaten gegeben. Es wird gezeigt, dass man leicht in Bedingungen gerlt, wo starke Uberkompensation eintritt und somit die angestrebte Verbesserung gegentiber dem an sich wenig befriedigende Ausgangszustand vie1 schlechter sein kann.