Analysis of ppb levels of organics in water by means of purge-and-trap, capillary gas chromatography and selective detectors

✍ Scribed by M. Duffy; J.N. Driscoll; S. Pappas; W. Sanford


Publisher
Elsevier Science
Year
1988
Tongue
English
Weight
432 KB
Volume
441
Category
Article
ISSN
1873-3778

No coin nor oath required. For personal study only.

✦ Synopsis


The Environmental Protection Agency (EPA) has issued a series of methods (500 and 600 series) for the analysis of organics in drinking water and industrial discharges. Methods 601 and 602 employ packed-column gas chromatography (GC) with electrolytic conductivity (E1CD) and photoionization detection (PID), respectively. A purge-and-trap system is used for concentration of volatiles. The EPA is in the process of converting methods 601 and 602 and certain 500-series methods to capillary column analysis. We have also initiated the conversion of a number of these methods, using E1CD and PID and have described them in detail in this paper. We have evaluated both 0.32- and 0.53-mm diameter capillary columns, using helium and nitrogen as carrier gases with each detector. We found that with nitrogen optimum results are obtained at a flow-rate of 15 ml/min, and with helium at 6-8 ml/min. As a result of system optimization, including operation of the two detectors in series, and converting from packed to capillary columns, we found that analysis time could be reduced from 80 min (for two methods separately) to ca. 30 min. In addition, the elution of more than five components in one peak, observed when the packed column specified in method 601 are used, was eliminated.


πŸ“œ SIMILAR VOLUMES


Determination of benzenes and naphthalen
✍ Trygg N. Barnung; Otto Grahl-Nielsen πŸ“‚ Article πŸ“… 1989 πŸ› Elsevier Science 🌐 English βš– 581 KB

A method for determination of volatile, aromatic hydrocarbons in the range from benzene to C2-naphthalenes has been adapted for monitoring the concentration of these components in water. The hydrocarbons are purged from the water by helium, trapped on an adsorbent, Tenax-GC, desorbed from this by ra

Selective removal of water in purge and
✍ Noij, Th. ;van Es, A. ;Cramers, C. ;Rijks, J. ;Dooper, R. πŸ“‚ Article πŸ“… 1987 πŸ› John Wiley and Sons 🌐 English βš– 502 KB

The design and features of an on-line purge and cold-trap preconcentration device for rapid analysis of volatile organic compounds in aqueous samples are discussed. Excessive water is removed from the purge gas by a condenser or a water permeable membrane in order to avoid blocking of the capillary

Identification of volatile organic compo
✍ Ilkka OjanperΓ€; Riikka HyppΓΆlΓ€; Erkki Vuori πŸ“‚ Article πŸ“… 1996 πŸ› Elsevier Science 🌐 English βš– 523 KB

A purge and trap concentrator with a Tenax trap was coupled to gas chromatography-Fourier transform infrared spectrometry for the identification of volatile organic compounds in blood samples. A styrene-divinyl benzene porous layer capillary column allowed the separation of compounds such as househo