Analysis of commercial dyes by capillary column supercritical fluid chromatography

โœ Scribed by Jackson, Wm. P. ;Later, D. W.


Publisher
John Wiley and Sons
Year
1986
Tongue
English
Weight
274 KB
Volume
9
Category
Article
ISSN
0935-6304

No coin nor oath required. For personal study only.

โœฆ Synopsis


High resolution separations of selected commercial azo, aniline, and anthraquinone dyes by capillary column supercritical fluid chromatography (SFC) are demonstrated. Supercritical n-pentane was used as a mobile phase and provided efficient separations of multi-functional, polar disperse dyes with molecular weights up to approximately 700 daltons.


๐Ÿ“œ SIMILAR VOLUMES


Analysis of mono-, di-, and triglyceride
โœ White, C. M. ;Houck, R. K. ๐Ÿ“‚ Article ๐Ÿ“… 1985 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 373 KB ๐Ÿ‘ 1 views

The separation of mixed mono-, di-, and triglycerides by capillary supercritical fluid chromatography is described. The separations were performed at low operating temperatures, using a carbon dioxide mobile phase, a conventional flame ionization detector, and two different stationary phases, DB-5 (

Separation of perfluorinated polyethers
โœ Naijun Wu; Yufeng Shen; Viorica Lopez-Avila; Milton L. Lee ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 222 KB ๐Ÿ‘ 2 views

Newly developed perfluorinated polyethers, HOCH O CF O CF 2 2 p 2 . x ลฝ . CF O CH OH Z-Dols , were separated using packed capillary column supercrit-2 q 2 ลฝ . ical fluid chromatography SFC . A fluorocarbon-bonded stationary phase, Fluofix ลฝ . 120N 5 m and 120 A , was used as a packing material and

The analysis of lubricating oil additive
โœ Ashraf, Sameena ;Bartle, Keith D. ;Clifford, Anthony A. ;Moulder, Robert ๐Ÿ“‚ Article ๐Ÿ“… 1992 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 334 KB ๐Ÿ‘ 1 views

## Abstract Lubricating oil additives have been analyzed by supercritical fluid chromatography on open tubular and packed capillary columns. Carbon dioxide and modified carbon dioxide were used as mobile phases and detection was accomplished by flame ionization and micro UV. Rapid and efficient ana

Trace analysis of agrochemicals by super
โœ Ashraf, Sameena ;Bartle, Keith D. ;Clifford, Anthony A. ;Moulder, Robert ๐Ÿ“‚ Article ๐Ÿ“… 1991 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 356 KB ๐Ÿ‘ 1 views

Capillary supercritical fluid chromatography was performed using solvent-vented injection in conjunction with a thermionic ionization detector. Mixtures of organo-nitrogen and phosphorus containing agrochemicals were chromatographed and detection of low picogram quantities was observed.