𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering

✍ Scribed by J. Biederer; M. Reuter; M. Both; C. Muhle; J. Grimm; J. Graessner; M. Heller


Book ID
113029241
Publisher
Springer
Year
2001
Tongue
English
Weight
741 KB
Volume
12
Category
Article
ISSN
0938-7994

No coin nor oath required. For personal study only.


📜 SIMILAR VOLUMES


Fat-suppressed T2-weighted MRI of the li
✍ Motoyuki Katayama; Takayuki Masui; Shigeru Kobayashi; Tatsuhiko Ito; Mamoru Taka 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 581 KB

## Abstract The purpose of our study was to compare the value of respiratory‐triggered fast spin‐echo, breath‐hold single‐shot fast spin‐echo, and breath‐hold fast‐recovery fast spin‐echo sequences in detecting hepatic lesions. Fat‐suppressed T2‐weighted magnetic resonance (MR) images obtained with

Comparison of breath-hold multishot echo
✍ Koichiro Yamakado; Hajime Sakuma; Shuichi Murashima; Atsuhiro Nakatsuka; Kaname 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 777 KB

## Abstract The purpose of this study was to evaluate the usefulness of multishot echo‐planar imaging in detecting liver tumors in comparison with respiratory triggered T2‐weighted fast‐spin‐echo (FSE) imaging. Thirty‐two patients with 70 focal liver lesions were imaged using a 1.5‐T high speed MR

T2-weighted MRI of the female pelvis: Co
✍ Takayuki Masui; Motoyuki Katayama; Shigeru Kobayashi; Harumi Sakahara; Tatsuhiko 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 441 KB

## Abstract In 49 patients who had pelvic abnormalities, breath‐hold T2‐weighted fast‐recovery (FR)‐fast spin‐echo (FSE) (imaging time = 24 sec) and nonbreath‐hold FSE MR images (2 min 8 sec) were compared qualitatively (on a four‐point scale) and quantitatively (using signal‐to‐noise ratios (SNRs)

T2-weighted MRI of rectosigmoid carcinom
✍ Shuhei Yamashita; Takayuki Masui; Motoyuki Katayama; Kimihiko Sato; Nobuko Yoshi 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 278 KB

## Abstract ## Purpose To compare the abilities of T2‐weighted (T2W) imaging using respiratory‐triggered fast spin‐echo (RT‐FSE), breathhold fast‐recovery FSE (BH‐FRFSE), and BH single‐shot FSE (BH‐SSFSE) sequences without an endorectal coil to detect rectosigmoid carcinomas. ## Materials and Met

T2-weighted breath-hold MRI of the liver
✍ Tae Kyoung Kim; Hyun Joo Lee; Hyun-Jung Jang; Ah Young Kim; Joon Koo Han; Byung 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 832 KB

To compare the clinical usefulness of T2-weighted breath-hold sequences for imaging the liver, 33 patients with 97 focal hepatic lesions were studied with a 1.0-T scanner by using T2-weighted breath-hold turbo spin-echo (SE) sequences and T2-weighted breath-hold half-Fourier single-shot turbo SE (HA