Heat transfer improvement in a water wall tube with "ns was investigated in a circulating #uidized bed (CFB) boiler. Experiments were "rst conducted in a 6 MWth CFB boiler then a model was developed to analyse and interpolate the results. Temperatures at some discrete points within the wall cross-se
An investigation of the heat transfer behavior of longitudinal finned membrane water wall tubes in circulating fluidized bed boilers
β Scribed by Anusorn Chinsuwan; Animesh Dutta
- Publisher
- Elsevier Science
- Year
- 2009
- Tongue
- English
- Weight
- 756 KB
- Volume
- 193
- Category
- Article
- ISSN
- 0032-5910
No coin nor oath required. For personal study only.
β¦ Synopsis
Circulating fluidized bed CFB Membrane water wall tube Finned tube Heat transfer coefficient CFB boilers
Experiments were conducted in a cold model circulating fluidized bed (CFB) having riser cross sectional area of 100 mm Γ 100 mm, height of 4.8 m, bed temperature of 75Β°C and superficial velocity of 8 ms -1 . Local sand having average diameter of 231 ΞΌm, particle density of 2774 kg m -3 and bulk density of 1515 kg m -3 was used as bed material. The experiments were conducted for three tube configurations: a membrane tube, a membrane tube with a longitudinal fin at the tube crest and a membrane tube with two longitudinal fins at 45Β°on both sides of the tube crest. Heat transfer, heat transfer coefficient ratio and heat transfer ratio of the three tubes are presented as a function of cross sectional average suspension density. The results show that membrane tubes with one and two longitudinal fins have higher heat transfer than membrane tubes although they have lower heat transfer coefficient. In addition, numerical simulations were conducted to investigate the heat transfer behavior of the three tubes under the normal operating conditions of CFB boilers. It was found that the membrane tube with two longitudinal fins at 45Β°on both sides of the tube crest had the flattest inner wall tube heat flux profile. Moreover, in terms of temperature distribution in the tube material, it has the lowest profile.
π SIMILAR VOLUMES
11 Process heating, power and incineration (energy applications in industry) different gas concentrations along the riser (02, CO, CH4, etc.), and the carbon combustion efficiency. The experimental results of carbon combustion efficiencies were compared with those predicted by the model and a good c