𝔖 Bobbio Scriptorium
✦   LIBER   ✦

An evaluation of low vapor pressure liquids for membrane introduction mass spectrometry

✍ Scribed by Johnson, R. C.; Koch, K.; Kasthurikrishnan, N.; Plass, W.; Patrick, J. S.; Cooks, R. G.


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
391 KB
Volume
32
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Four liquids of low vapour pressure have been examined for use as semi-permeable membranes in the sampling and analysis of volatile organic compounds by the technique of membrane introduction mass spectrometry (MIMS). The chosen liquids are inert and hydrophobic and can be formed to any desired thickness or shape. The selected polymersÈpolyphenyl ether, alkylated cyclopentane, perÑuorinated ether and silicone oilÈwere supported on a microporous substrate and mounted in a direct insertion membrane probe. Polyphenyl ether, alkylated cyclopentane and silicone oil each formed stable semi-permeable barriers which passed the analytes of interest while discriminating strongly against the water solvent. These highly stable liquids also showed no signiÐcant loss of mass or contribution to the background of the mass spectrometer. Optimal injection volumes (2.25 ml) and membrane temperatures (90 ÄC) gave 10% -90% rise times of 44-55 s for the three liquids compared with 35 s for a reference silicone membrane. Comparable detection limits at the low-ppb level were observed for benzene, toluene, trans-1,2dichloroethylene, chlorobenzene, carbon tetrachloride and nitrobenzene using the silicone reference and alkylated cyclopentane membranes.


📜 SIMILAR VOLUMES


Evaluation of gas chromatography coupled
✍ Gavin O'Connor; Steve J. Rowland; E. Hywel Evans 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 320 KB 👁 2 views

Evaluation of gas chromatography coupled with low pressure plasma source mass spectrometry for the screening of volatile organic compounds in food A number of ion sources, namely low pressure helium MIPs, and low pressure helium and argon ICPs, coupled to GC and mass spectrometry have been evaluated

An automated method for the simultaneous
✍ Kiyoshi Kawabata; Nobuko Matsushima; Kunihiro Sasahara 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 166 KB 👁 2 views

A new method for the determination of pravastatin, a potent inhibitor of 3-hydroxy-3-methylglutaryl coenzyme A (HMG-CoA) reductase, and its main metabolite (R-416) in human plasma using high-performance liquid chromatography/atmospheric pressure (negative ion) chemical ionization mass spectrometry (