An efficient chemical shift imaging scheme for magnetic resonance-guided neurosurgery
✍ Scribed by Haiying Liu; Walter A. Hall; Alastair J. Martin; Charles L. Truwit
- Publisher
- John Wiley and Sons
- Year
- 2001
- Tongue
- English
- Weight
- 298 KB
- Volume
- 14
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
An efficient magnetic resonance spectroscopic imaging (MRSI) or chemical shift imaging (CSI) technique based on multiple spin echoes (MSE) has been implemented, validated, and used in both phantom and in vivo MR‐guided neurosurgical applications. The key concept of the method is to employ MSE to significantly speed up the data collection rate for mapping hydrogen‐containing metabolites. Using an echo train length (ETL) of three per excitation to simultaneously fill three consecutive k‐space areas, the total scan time for a spectroscopic image matrix size of 32 × 32 has been shortened to approximately 11 minutes. An interecho spacing time of 273 msec was used to null the phase anomalies of lactate double peaks due to the J‐coupling. This allowed a sufficient long data sampling time to achieve 4 Hz spectral resolution. Performing CSI intraopertively during an MR‐guided neurosurgical procedure was shown to be feasible at 1.5 T. More importantly, it was shown that more relevant information can be obtained regarding neurochemistry about a targeted lesion, in addition to conventional MR morphological imaging noninvasively. In 25 MR‐guided neurosurgical cases, the alleviated choline signal has been found to be consistent with the existence of rapid tumor cell proliferation in the corresponding area. The actual neurobiopsy guided by the spectroscopic imaging method demonstrated that it could provide valuable information in specifying the optimal site in a biopsy procedure, especially in the case involving a nonenhancing tumor. The multiecho scheme has made the CSI technique efficient enough to be routinely used in MR‐guided surgical procedures at 1.5 T and also allows the possibility of taking full advantage of MRI capability. J. Magn. Reson. Imaging 2001;14:1–7. © 2001 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
Multiecho sequences are widely used in MRI because they are an efficient means of acquiring data and they can be used to quantitatively estimate Tz. However, the uniformity of each image and the accuracy of each T2 estimate may be corrupted by several instrumental factors such as rfpulse imperfectio
An alternative scheme in acquiring 13 C spectroscopic images ventional means using coplanar concentric surface coils ( 7). using inverse detection via polarization transfer through protons In other studies, proton-enhanced schemes by polarization was proposed and experimentally verified by a phantom
## Abstract ## Purpose To determine whether chemical‐shift‐selective (CSS) fat suppression is necessary for ferumoxide‐enhanced T2‐weighted fast spin‐echo (FSE) imaging in the detection of malignant hepatic tumors. ## Materials and Methods Ferumoxide‐enhanced magnetic resonance (MR) images obtai