An Automated System for monitoring the Quality and Quantity of Subsurface Drain Flow
β Scribed by R.S. Kanwar; D. Bjorneberg; D. Baker
- Publisher
- Elsevier Science
- Year
- 1999
- Tongue
- English
- Weight
- 172 KB
- Volume
- 73
- Category
- Article
- ISSN
- 0021-8634
No coin nor oath required. For personal study only.
β¦ Synopsis
An automated #ow data collection system was installed in a subsurface drainage system to determine discharge volumes and drainage #ow rates. An experimental site was established by installing a subsurface drainage system on 36 plots, each of 0)4 ha, to measure subsurface drain #ows and collect drain water samples for water quality analysis. Subsurface drains from individual plots were intercepted at the end of plots and routed to individual sumps to collect drain water. Flowmeters connected to individual sump pumps measured the volume of water pumped from these sumps. Electronic outputs of the #owmeters were recorded with data loggers, and readings of the analog registers were recorded manually. The data loggers recorded the time when each sump pump started and stopped pumping water. Data collected by data loggers were used to calculate drain discharge volumes and drain #ow rates. This monitoring system was evaluated by comparing the drain volume rates between #owmeter readings and the data collected by data loggers for some rain events.
Subsurface drain #ow measured by the data logger system was not signi"cantly di!erent from the manual readings taken by the #owmeters. The data logger system was an e!ective method for measuring changes in subsurface drain #ow rates over short time periods and drain #ow response to individual rainfall events. This automated system was also used to monitor the movement of nitrate}nitrogen (NO }N) to subsurface drain water.
π SIMILAR VOLUMES
A flow system for voltammetric analysis is described and characterized. This system was designed so that sample manipulation and electrochemical experiments could be performed under automated control. The goal of this work is to expand the practical possibilities for elucidation of the electrochemic
A flow-injection system with immobilized dehydrogenases, including sample pretreatments by means of a continuously working filtration unit for elimination of microorganisms and a dialyser, was applied to the parallel determination of glucose and ethanol during a baker's yeast fermentation. The syst
## Abstract A fully automated anthrax smoke detector (ASD) has been developed and tested. The ASD is intended to serve as a cost effective frontβend monitor for anthrax surveillance systems. The principle of operation is based on measuring airborne endospore concentrations, where a sharp concentrat
An automated system for the contmuous momtormg of ammonmm eon m fish farming plant sea water IS described The sample IS Introduced mto a carrier stream by an automated sample Injector and merged with a reagent solution contammg sochum sahcylate and sodium mtroprusslde The sample stream IS then muted