𝔖 Bobbio Scriptorium
✦   LIBER   ✦

An Automated High-Performance Liquid Chromatography Fluorescence Method for the Analyses of Endothelins in Plasma Samples

✍ Scribed by Prem Kumarathasan; Patrick Goegan; Renaud Vincent


Publisher
Elsevier Science
Year
2001
Tongue
English
Weight
82 KB
Volume
299
Category
Article
ISSN
0003-2697

No coin nor oath required. For personal study only.

✦ Synopsis


A high-performance liquid chromatographic method with fluorescence detection was developed to simultaneously analyze endothelins, a class of vasoactive peptides, in plasma samples. Sample preparation for HPLC analysis was carried out by initial stabilization of blood and plasma samples against transformation of big endothelins to mature endothelins and breakdown of mature endothelins by serine proteases, as well as oxidative modifications of endothelins. Deproteinization of plasma samples was achieved with acidified acetone, and the samples were further purified on molecular weight cutoff filters. Endothelins were separated on a reversed phase LC-318 column by gradient elution using a mobile phase containing acetonitrile and water (0.1% trifluoroacetic acid) and were analyzed by fluorescence detection (lambda(Ex), 280 nm; lambda(Em), 340). Limit of detection values were in the range of 0.2-0.5 pmol. Linear (R(2), 0.99) calibration curves were established for analyte amounts in the range of 1 to 100 pmols. Recoveries of endothelins from spiked plasma samples analyzed ranged from 60-95%. Under optimized conditions the HPLC-fluorescence method was determined to be sensitive and specific for the analysis of big endothelin-1, endothelin-1, endothelin-2, and endothelin-3 in plasma. Simultaneous measurement of these endothelins by the HPLC method should permit a better understanding of their specific roles and relationships under various pathological conditions.


📜 SIMILAR VOLUMES


An automated analyzer for vancomycin in
✍ Mitsue Saito; Tomofumi Santa; Makoto Tsunoda; Hiroshi Hamamoto; Noriko Usui 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 77 KB 👁 2 views

## Abstract An automated analyzer for vancomycin in rat plasma by column‐switching high‐performance liquid chromatography (HPLC) with UV detection was developed. The method includes in‐line extraction of vancomycin by ion‐exchange cartridge column and a separation on a reversed‐phase column with UV

An automated method for the determinatio
✍ Walter A. Hunt; Thomas K. Dalton 📂 Article 📅 1983 🏛 Elsevier Science 🌐 English ⚖ 474 KB

An automated high-performance liquid chromatographic method has been developed that allows for the determination of a number of compounds related to catechol- and indoleamine metabolism. The compounds that can be measured include L-DOPA, dopamine, dihydroxyphenylacetic acid, homovanillic acid, 3-met

A reversed phase high-performance liquid
✍ Pecavar, Anika ;Šmidovnik, Andrej ;Milivojevic, Dušan ;Prošek, Mirko 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 373 KB 👁 1 views

## Abstract A reversed‐phase HPLC method for the analysis of cephalexin (7‐[(aminophenylacetyl)amino]‐3‐methyl‐8‐oxo‐5‐thia‐1‐azabicyclo[4.2.0]oct‐2‐ene‐2‐carboxylic acid) by isocratic separation is described. A comparison is made between the ultrafiltration land the extraction procedure developed

High-performance liquid chromatography t
✍ Cristina Sottani; Claudio Minoia; Maurizio D'Incalci; Massimiliano Paganini; Mas 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 88 KB 👁 3 views

A sensitive, specific, accurate and reproducible analytical method was developed and validated for the quantitation of the anticancer agent paclitaxel in human plasma. This procedure is based on high performance liquid chromatography/ion spray -tandem mass spectrometry. This methodology is highly sp