Ambient imaging mass spectrometry by electrospray ionization using solid needle as sampling probe
✍ Scribed by Lee Chuin Chen; Kentaro Yoshimura; Zhan Yu; Rikiya Iwata; Hajime Ito; Hiroaki Suzuki; Kunihiko Mori; Osamu Ariyada; Sen Takeda; Takeo Kubota; Kenzo Hiraoka
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 515 KB
- Volume
- 44
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.1632
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Although being an atmospheric pressure ion source, electrospray ionization (ESI) has rarely been used directly for ambient imaging mass spectrometry because the sample has to be introduced as liquid solution through the capillary. Instead of capillary, probe electrospray ionization (PESI), which has been developed recently, uses a solid needle as the sampling probe, as well as the electrospray emitter, and has been applied not only for liquid solutions but also for the direct sampling on wet samples. Biological tissues are composed of cells that contain 70–90% water, and when the surface is probed by the needle tip, the biological fluid adhering to the needle can be electrosprayed directly or assisted by additional solvent added onto the needle surface. Here, we demonstrate ambient imaging mass spectrometry of mouse brain section using PESI, incorporated with an auxiliary heated capillary sprayer. The solvent vapor generated from the sprayer condensed on the needle tip, re‐dissolving the adhered sample, and at the same time, providing an indirect means for needle cleaning. The histological sections were prepared by fixation using paraformaldehyde, and the spatial analysis was automated by maintaining an equal sampling depth into the sample in addition to raster scan. Phospholipids and galactosylceramides were readily detected from the mouse brain section in the positive ion mode, and were mapped with 60 µm lateral resolution to form mass spectrometric images. Copyright © 2009 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
## Abstract Two model peptides, des‐Arg1‐bradykinin (DAB) and bradykinin (B), were cationized by Ag^+^ after their separation by reversed‐phase liquid chromatography (RPLC) prior to mass spectrometry (MS). Silver nitrate solution was used as a post‐column reagent. The RPLC and MS experimental condi
## Abstract Triacylglycerols (TAGs) provide a challenge for mass spectrometry (MS) analysis because of their complexity. In particular, for dietary, nutritional and metabolic purposes, the positional placement of fatty acids on the glycerol backbone of TAGs is a crucial aspect. To solve this proble