Adrenal tissue characterization with 0.5-T MR imaging: Value of T2*-weighted images
✍ Scribed by Tomoaki Ichikawa; Hajime Fujimoto; Koji Murakami; Mikio Tauchi; Shigeru Mochizuki; Kuni Ohtomo; Guio Uchiyama
- Publisher
- John Wiley and Sons
- Year
- 1993
- Tongue
- English
- Weight
- 420 KB
- Volume
- 3
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The authors investigated the value of magnetic resonance (MR) imaging at 0.5 T for distinguishing adrenal adenomas from adrenal metastases. The series included 23 adrenal adenomas (18 nonhyperfunctioning, five hyperfunctioning) and 23 adrenal metastases from various organs. Adrenal tumor–liver signal intensity ratios on T1‐, T2‐, and T2*‐weighted images were calculated for adrenal tissue characterization. Adrenal adenomas were more precisely distinguished from adrenal metastases on T2*‐weighted images (21 of 23, 91%) than on T2‐weighted images (15 of 23, 65%). T1‐weighted images were not useful for this distinction. In conclusion, T2*‐weighted images were better than routine T2‐weighted images for distinguishing adrenal adenomas from adrenal metastases. It can be postulated that the total signal intensity of adrenal adenomas, which contain some fat components, decreased on T2*‐weighted images because of an out‐of‐phase effect.
📜 SIMILAR VOLUMES
## Abstract Three magnetic resonance (MR) imaging techniques (T1‐weighted, T2‐weighted, and T1‐weighted gadopentetate dimeglumine—enhanced) were compared in 32 consecutive MR imaging studies of 26 patients with suspected musculoskeletal masses. T2‐weighted images were superior to T1‐weighted enhanc
## Abstract ## Purpose To evaluate the clinical value of diffusion‐weighted imaging (DWI) and dynamic MRI in combination with T2‐weighted imaging (T2W) for the detection of prostate cancer. ## Materials and Methods A total of 83 patients with elevated serum prostate specific antigen (PSA) levels
## Abstract An inversion recovery true fast imaging with steady precession (FISP) pulse sequence was developed to carry out fast imaging of the lungs at 0.2 T. Using this sequence, oxygen‐enhanced magnetic resonance (MR) lung imaging was performed on healthy volunteers. The lungs showed signal enha