𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Adiabatic refocusing pulses for volume selection in magnetic resonance spectroscopic imaging

✍ Scribed by Laura I. Sacolick; Douglas L. Rothman; Robin A. de Graaf


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
761 KB
Volume
57
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Because of their excellent slice profiles and high immunity to RF inhomogeneity, adiabatic full passage (AFP) pulses are ideal for use in spatial localization. The nonlinear, position‐dependent phase of a single AFP pulse generated during refocusing of transverse magnetization traditionally is eliminated by using identical pairs of AFP pulses, at the expense of increased RF power deposition and increased echo time (TE). Here it is shown that one can achieve significant phase refocusing by executing single AFP pulses along non‐equivalent spatial axes. When used for volume selection in MR spectroscopic imaging (MRSI) the remaining nonlinear phase becomes inconsequential when the phase across a spectroscopic volume is small. Selection of rectangular and octagonal volumes is demonstrated with half the number of AFP pulses used in the traditional approach. It is shown that octagonal volume selection in the human brain provides excellent suppression of extracranial lipids, and thus allows multislice ^1^H MRSI at 4 Tesla to be performed within the guidelines for RF power deposition. Magn Reson Med 57:548–553, 2007. © 2007 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Self-refocusing 270° gaussian pulses for
✍ Lyndon Emsley; Geoffrey Bodenhausen 📂 Article 📅 1989 🏛 John Wiley and Sons 🌐 English ⚖ 537 KB

It is demonstrated, on the grounds of simulations, how 270" Gaussian pulses can be used for slice selection in nuclear magnetic resonance imaging experiments. It is shown that the usual gradient reversal procedure can be omitted if the selective 90" pulse normally used is replaced by a self-refocusi

Venous refocusing for volume estimation:
✍ Bojana Stefanovic; G. Bruce Pike 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 585 KB

## Abstract A novel, noninvasive magnetic resonance imaging‐based method for measuring changes in venous cerebral blood volume (CBV~v~) is presented. Venous refocusing for volume estimation (VERVE) exploits the dependency of the spin–spin relaxation rate of deoxygenated blood on the refocusing inte

On the use of a slice-selective 270° sel
✍ David M. Doddrell; Graham J. Galloway; Stephen E. Rose; Peter J. Moulds; Ian M. 📂 Article 📅 1991 🏛 John Wiley and Sons 🌐 English ⚖ 254 KB 👁 1 views

Theoretical and experimental results are presented demonstrating that the slice intensity resulting from a self-refocusing 270" Gaussian pulse (L. Elmsley and G. Bodenhausen, Magn. Reson. in Med. 10, 273, 1989) is approximately 60% of that following an appropriately refocused 90" GaUSSian pulse.

Power efficient on-resonance saturation
✍ Jintong Mao; J. Ray Ballinger 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 598 KB

## Abstract A family of new on‐resonance saturation pulses for magnetization transfer in MRI is proposed. These pulses can be represented as a product of a shaped function and a cosine function. The shaped function can have many different forms, one of which is a Gaussian function. The experimental