𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Adhesion to chondroitinase ABC treated dentin

✍ Scribed by Annalisa Mazzoni; David H. Pashley; Alessandra Ruggeri Jr.; Francesca Vita; Mirella Falconi; Roberto Di Lenarda; Lorenzo Breschi


Book ID
102297799
Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
257 KB
Volume
86B
Category
Article
ISSN
1552-4973

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Dentin bonding relies on complete resin impregnation throughout the demineralised hydrophilic collagen mesh. Chondroitin sulphate‐glycosaminoglycans are claimed to regulate the three‐dimensional arrangement of the dentin organic matrix and its hydrophilicity. The aim of this study was to investigate bond strength of two etch‐and‐rinse adhesives to chondroitinase ABC treated dentin. Human extracted molars were treated with chondroitinase ABC and a double labeling immunohistochemical technique was applied to reveal type I collagen and chondroitin 4/6 sulphate distribution under field emission in‐lens scanning electron microscope. The immunohistochemical technique confirmed the effective removal of chondroitin 4/6 sulphate after the enzymatic treatment. Dentin surfaces exposed to chondroitinase ABC and untreated specimens prepared on untreated acid‐etched dentin were bonded with Adper Scotchbond Multi‐Purpose or Prime and Bond NT. Bonded specimens were submitted to microtensile testing and nanoleakage interfacial analysis under transmission electron microscope. Increased mean values of microtensile bond strength and reduced nanoleakage expression were found for both adhesives after chondroitinase ABC treatment of the dentin surface. Adper Scotchbond Multi‐Purpose increased its bond strength about 28%, while bonding made with Prime and Bond NT almost doubled (92% increase) compared to untreated specimens. This study supports the hypothesis that adhesion can be enhanced by removal of chondroitin 4/6 sulphate and dermatan sulphate, probably due to a reduced amount of water content and enlarged interfibrillar spaces. Further studies should validate this hypothesis investigating the stability of chondroitin 4/6 and dermatan sulphate‐depleted dentin bonded interface over time. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2008


📜 SIMILAR VOLUMES


Bond strength of adhesive restorations t
✍ D. A. M. P. Malta; M. A. M. Kreidler; G. E. Villa; M. F. de Andrade; C. R. Fonta 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 77 KB

Background and Objective: evaluate the adhesion of adhesive restorations with and without a base of resin-modified glass-ionomer cement (RMGIC) to dentin irradiated with Er:YAG laser. Study Design/Materials and Methods: Twenty-four human molar teeth were divided into 6 groups (n=4): G1) 37% Phospho