𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Acute biological response to laser balloon angioplasty in the atherosclerotic rabbit

✍ Scribed by Dimitrios Alexopouios; Dr. Timothy A. Sanborn; Jonathan D. Marmur; Juan J. Badimon; Una Badimon; Renate Dische; Valentin Fuster


Publisher
John Wiley and Sons
Year
1994
Tongue
English
Weight
693 KB
Volume
14
Category
Article
ISSN
0196-8092

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Laser balloon angioplasty with Nd:YAG energy has been proposed as a method to seal intimal dissection and prevent elastic recoil after balloon angioplasty. To better define the vessel response to laser balloon angioplasty, its effects on luminal diameter, Indium‐111 labelled platelet deposition, and histology were studied in 10 atherosclerotic rabbits. Balloon angioplasty was performed in both iliac arteries and was followed by laser balloon angioplasty in only one iliac artery. The nonlased artery served as a control. Single (15–35 W for 20 sec) or repetitive laser pulses (12–25 W for 20 sec × 3) were used. Platelet deposition was quantified 2 hr after the intervention. Lumen diameter (mm) increased following balloon angioplasty from 0.99 ± 0.47 (mean ± SD) to 1.92 ± 0.43 and 0.89 ± 0.46 to 1.99 ± 0.57 in the balloon and laser‐treated arteries, respectively (P < 0.001 for both groups for comparisons to baseline, P = NS for between groups comparison). Laser balloon angioplasty resulted in a further increase in luminal diameter to 2.42 ± 0.53 (P < 0.02) when compared to the post balloon angioplasty diameter. Platelet deposition (10^6^/cm vessel) was higher following laser balloon angioplasty (26.9, 10.2–189; median range) than after balloon angioplasty (10.6, 3.4–30), P < 0.001. Histologic evidence of laser “sealing” was present in only one artery. Thus although laser balloon angioplasty results in an improved lumen diameter, it is accompanied by increased platelet deposition. In the atherosclerotic rabbit model, abolition of vascular recoil rather than “sealing” seems to be the most important advantage of laser balloon angioplasty over conventional balloon angioplasty. © 1994 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


In-vivo response to free electron laser
✍ Cynthia A. Toth; Eric K. Chiu; Katrina P. Winter; Michelle N. McCall; Sarah F. B 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 276 KB 👁 1 views

## Abstract ## Background and Objective We analyzed the in vivo ocular response to corneal incisions made by Medical Free Electron Laser (MFEL) as a function of scan rate and incision depth. Additionally, we compared biomicroscopy, optical coherence tomography (OCT), and light microscopy as ocular

Primary stent implantation is superior t
✍ Shigeru Saito; George Hosokawa; Shinji Tanaka; Sunao Nakamura 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 91 KB 👁 2 views

Several studies have shown that stent implantations in acute myocardial infarction (AMI) result in better short-and long-term outcomes than primary balloon angioplasty. These results, however, have not been ascertained in randomized trials. We randomized 136 patients out of 208 patients with AMI wit