## Abstract MR tracking of a vascular guidewire sized for a .035‐inch (.89‐mm) catheter lumen was performed. The guidewire was actively tracked by incorporation of a miniature radiofrequency (RF) receive coil built into its tip. After in vitro validation, simultaneous tracking of the guidewire and
Active MR visualization of a vascular guidewire in vivo
✍ Scribed by Mark E. Ladd; Gesine G. Zimmermann; Harald H. Quick; Jörg F. Debatin; Peter Boesiger; Gustav K. von Schulthess; Graeme C. McKinnon
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 884 KB
- Volume
- 8
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
The purpose of this study was development of an actively visualized .035-inch vascular guidewire for use in MR-guided interventions. The guidewire was actively visualized by inclusion of a 6-cm-long radiofrequency coil in its tip. A high contrast outline of the distal tip of the guidewire was obtained by acquiring an image with the radiofrequency coil as the receiving antenna. The position of the guidewire relative to the surrounding anatomy was determined by overlaying the guidewire image on a previously acquired road map. The guidewire was evaluated in vivo in the abdominal vessels of a rabbit and swine at 1.5 T. The built-in radiofrequency coil delivered a high contrast signal over its full length, enabling visualization of the position and curvature of the tip of the guidewire. The ability to see the curvature of the guidewire over several centimeters significantly eased manipulation into targeted vessels and represents an important advance toward MR-guided vascular interventions.
📜 SIMILAR VOLUMES
## Abstract Vessel‐wall measurements from multicontrast MRI provide information on plaque structure and evolution. This requires the extraction of numerous contours. In this work a contour‐extraction method is proposed that uses an active contour model (NLSnake) adapted for a wide range of MR vascu
The purpose of this study was to assess the feasibility of a newly developed field inhomogeneity catheter for interventional MRI in vivo. Different prototypes of a field inhomogeneity catheter (pigtail and multipurpose configuration, balloon catheters) were investigated in pigs. The catheters were i