## Abstract An important source of MRI acoustic noise—magnet cryostat warm‐bore vibrations caused by eddy‐current‐induced forces—can be mitigated by a passive metal shield mounted on the outside of a vibration‐isolated, vacuum‐enclosed shielded gradient set. Finite‐element (FE) calculations for a _
Active acoustic control in gradient coils for MRI
✍ Scribed by P. Mansfield; B. Haywood; R. Coxon
- Publisher
- John Wiley and Sons
- Year
- 2001
- Tongue
- English
- Weight
- 268 KB
- Volume
- 46
- Category
- Article
- ISSN
- 0740-3194
- DOI
- 10.1002/mrm.1261
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The new principles of active acoustic control in gradient coil design recently introduced by Mansfield and Haywood (MAGMA 1999;8(Suppl 1):55) are further developed theoretically for the far‐field acoustic output for a single sector of a coil system comprising four or more flat rectangular coil sectors. Each sector consists of a split plate arrangement in which are embedded two windings, an outer primary winding and a narrow inner re‐entrant loop control winding immediately adjacent to and surrounding the split or air gap. The wire spacing of the control winding is made small so as not to affect substantially the magnetic field created by the primary winding. Experimental results are presented for two sectors each made of a different readily available plastic material and tested over a range of frequencies. They both show substantial average reductions in acoustic output over the full output when the control winding is appropriately driven. New theoretical expressions are derived for particular frequencies based on normal mode expansions for the plate. This new approach is better able to explain the acoustic output difference between the full and reduced output modes. Empirical expressions are also developed which include longitudinal as well as transverse plate characteristics and used to fit the experimental acoustic output data as a function of frequency and indicate good agreement with regard to both the form and amplitude of the acoustic output response. Magn Reson Med 46:807–818, 2001. © 2001 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Combining positron emission tomography (PET) and MRI necessarily involves an engineering tradeoff as the equipment needed for the two modalities vies for the space closest to the region where the signals originate. In one recently described scanner configuration for simultaneous positro
## Abstract We have designed and constructed a quiet gradient set with restricted access for the combined purposes of evaluating the principles of active acoustic screening, recently introduced by Mansfield, Glover, and Bowtell, and for EPI studies of the head at 3.0 T. The design utilizes the retu
## Abstract The concept of active acoustic control was recently introduced by Mansfield and Haywood (MAGMA 2000:10:147–151) to ameliorate the problem of acoustic noise from MRI, particularly that from high‐speed EPI. A 30 dB reduction in noise was previously achieved with the use of acoustic contro