𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Acid phosphatase/glucose oxidase-based biosensors for the determination of pesticides

✍ Scribed by Franco Mazzei; Francesco Botrè; Claudio Botrè


Publisher
Elsevier Science
Year
1996
Tongue
English
Weight
634 KB
Volume
336
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


This work presents new amperomettic bienzymatic bioelectrodes for the determination of organophosphorus and carbamic acid type pesticides. Two different kinds of bienzymatic bioelectrodes are presented: a classical bienzymatic electrode, obtained by physicochemical immobilization of purified acid phosphatase (AP) and glucose oxidase (GOD) on the tip of an amperometric H202 electrode; and a hybrid biosensor, in which AP has been employed in the form of a thin layer of potato (Solanum tuberosum) tissue, endowed with a high content of enzyme activity. Both the biosensors can selectively detect glucose-6-phosphate (G6P), in the 5.0 x 1 O-5-1 .2x lo-' M concentration range. Pesticides are detected, thanks to their high inhibition power towards AP, evaluated by adding the sample stepwise to a buffered solution of G6P, and recording the corresponding current change. The detection limit is therefore a function of the type of pesticide, but it can be as low as 1 pg 1-l in the case of organophosphorus compounds. The detection limit is generally higher for carbamates, as a consequence of their weaker inhibition power towards acid phosphatase. Both bioelectrodes presented comparable values of the main physicochemical and analytical parameters evaluated for assessing their overall performance; nonetheless the plant tissue based bioelectrode exhibited a longer shelf life and a better reliability of the amperometric results.


📜 SIMILAR VOLUMES


A Combined Cellobiose Oxidase/Glucose Ox
✍ M. Nordling; M. Elmgren; J. Stahlberg; G. Pettersson; S.E. Lindquist 📂 Article 📅 1993 🏛 Elsevier Science 🌐 English ⚖ 633 KB

Highly specific biosensors can be prepared by immobilizing flavin-containing oxidases in a redox polymer on an electrode surface. By combining one glucose oxidase and one cellobiose oxidase electrode in a flow cell we have made a sensor for flow-injection analysis, or postcolumn quantification, of g

Amperometric flow-through biosensor for
✍ C. La Rosa; F. Pariente; L. Hernández; E. Lorenzo 📂 Article 📅 1995 🏛 Elsevier Science 🌐 English ⚖ 674 KB

An amperometric flow-through biosensor for the determination of pesticides is proposed. It is based on the inhibition of the acetyl cholinesterase-catalysed hydrolysis of 4-aminophenylacetate. The calibration graphs were linear from 5.0 X lo-' to 1.0 x lop5 M and 5.0 X lo-' to 5.0 X lo-' M for paro

Peroxidase based amperometric biosensors
✍ Franco Mazzei; Francesco Botrè; Giampiero Lorenti; Fernando Porcelli 📂 Article 📅 1996 🏛 Elsevier Science 🌐 English ⚖ 512 KB

This work presents the realization of enzymatic bioelectrodes, suitable for the determination of y-aminobutyric acid (GABA). The biosensors are based on the catalytic activity of the enzymes y-aminobutyric glutamic transaminase (GABA-T), succinic semialdehyde dehydrogenase (SSDH) and horseradish per