𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Accurate mass determination: sensitive and volatile references for positive-ion chemical ionization and negative-ion electrospray mass spectrometry

✍ Scribed by Hideji Fujiwara; Robert C. Chott; Ronn G. Nadeau


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
143 KB
Volume
11
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

✦ Synopsis


Accurate mass analysis at high resolution can be used to determine elemental compositions and is often essential for conclusive metabolite identification. Reference standards can play an important role in the success of the analysis. We have discovered that perfluorinated acid anhydride/fluorinated alkylalcohol (PF-anh/F-alc) derivatives of glyphosate and aminomethylphosphonic acid are sensitively analysed by negative-ion electrospray ionization (ESI) and by positive-ion chemical ionization (CI). Based upon these results, PF-anh/F-alc derivatives of amino acids and PF-anh derivatives of primary amines were prepared, greatly expanding our collection of reference standards for accurate mass measurements. Sample ions are not suppressed since the reference standards can be selected based upon a narrow mass range of interest. They are volatile and, due to the degree of fluorination, have accurate masses favourably close to nominal mass. They are adequately soluble in reverse phase high-performance liquid chromatography solvents, making them particularly useful for ESI. Several examples of positive-ion CI and negative-ion electrospray MS accurate mass analyses of metabolites, obtained using the PF-anh/F-alc derivatives, are described.


πŸ“œ SIMILAR VOLUMES


Chloride anion attachment in negative io
✍ Richard B. Cole; Junhua Zhu πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 67 KB πŸ‘ 2 views

An approach to enable negative ion electrospray ionization (ESI) mass spectrometric detection of analytes that lack acidic sites and thus exhibit weak [MΓ€H] Γ€ signals has been developed. The method relies upon attachment of Cl Γ€ ions present in electrosprayed solutions of chlorinated solvents such a

Determination of anabolic steroids by ga
✍ Man Ho Choi; Bong Chul Chung; Won Lee; Un Chul Lee; Yunje Kim πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 118 KB πŸ‘ 2 views

A gas chromatography/mass spectrometry (GC/MS) method is described which uses negative ion chemical ionization (NCI) and tandem mass spectrometry (MS/MS) for the determination of eight anabolic steroids in human urine. Eight anabolic steroids were derivatized by heptafluorobutyric anhydride (HFBA),