Accuracy of registration methods in frameless stereotaxis
β Scribed by Patrick A. Helm; Timothy S. Eckel
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 169 KB
- Volume
- 3
- Category
- Article
- ISSN
- 1092-9088
No coin nor oath required. For personal study only.
β¦ Synopsis
The accuracy of image to patient registration is a critical issue in the intraoperative use of frameless stereotaxic instruments for surgical guidance. This study was performed to assess the accuracy of image to head phantom registration using several standard registration techniques and a clinical frameless stereotaxic instrument. Two types of radioopaque fiducial markers were fixed to a plastic head phantom, and a computed tomography scan of the phantom was performed in the routine fashion. Image to phantom registration was carried out using fiducial markers, fiducial markers plus surface fit, anatomic landmarks, and anatomic landmarks plus surface fit. After each registration, linear inaccuracy measurements were performed for each of 32 markers. Each registration was performed 10 times, and the overall mean error measurements and anterior and posterior error were computed and compared. The overall mean error was smallest for the fiducial registration alone (2.07 mm). The magnitude of error increased significantly for posterior locations for all other registration techniques, but it was not significantly increased for the fiducial registration method. For this hardware configuration, registration with surface-applied fiducial markers is measurably more accurate than registration with surface anatomic landmarks. The addition of surface points to the fiducial registration does not increase the registration accuracy but, in fact, increases the degree of error.
π SIMILAR VOLUMES
The accuracy of a semipermanent fiducial marker system developed at Wayne State University in collaboration with Fisher-Leibinger (Freiburg, Germany) was compared with reference to a standard stereotactic frame (Zamorano-Dujovny Localizing Unit; Fisher-Leibinger). For each patient in our study, 10 s
## Abstract Completeness of reporting and accuracy of the diagnosis of ovarian cancer from one health region in Norway to the Cancer Registry were examined. Data kept by the Cancer Registry were evaluated against discharge diagnosis data from all 8 hospitals in the health region during the period o