## Abstract Conventional phase‐contrast velocity mapping in the ascending aorta was combined with __k‐t__ BLAST and __k‐t__ SENSE. Up to 5.3‐fold net acceleration was achieved, enabling single breath‐hold acquisitions. A standard phase‐contrast (PC) sequence with interleaved acquisition of the velo
Accelerating cardiac cine 3D imaging using k-t BLAST
✍ Scribed by Sebastian Kozerke; Jeffrey Tsao; Reza Razavi; Peter Boesiger
- Publisher
- John Wiley and Sons
- Year
- 2004
- Tongue
- English
- Weight
- 880 KB
- Volume
- 52
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
By exploiting spatiotemporal correlations in cardiac acquisitions using k-t BLAST, gated cine 3D acquisitions of the heart were accelerated by a net factor of 4.3, making single breathhold acquisitions possible. Sparse sampling of k-t space along a sheared grid pattern was implemented into a cine 3D SSFP sequence. The acquisition of low-resolution training data, which was required to resolve aliasing in the k-t BLAST method, was either interleaved into the sampling process or obtained in a separate prescan to allow for shorter breathhold durations in patients with heart disease. Volumetric datasets covering the heart with 20 slices at a spatial resolution of 2 x 2 x 5 mm3 were recorded with 20 cardiac phases in a total breathhold duration of 25-27 sec, or 18 sec if partial Fourier sampling was additionally employed. The feasibility of the method was demonstrated on healthy volunteers and on patients. The comparison of endocardial area derived from single slices of the 3D dataset with values extracted from separate single-slice acquisitions showed no significant differences. By shortening the acquisition substantially, k-t BLAST may greatly facilitate volumetric imaging of the heart for evaluation of regional wall motion and the assessment of ventricular volume and ejection fraction.
📜 SIMILAR VOLUMES
We describe a technique for three-dimensional cine MR imaging. By using short repetition times (TR) and interleaved slice encoding, volumetric cine data can be acquired throughout the cardiac cycle with a temporal resolution of approximately 80 msec. A T1-shortening agent is used to produce contrast
## Abstract ## Purpose To compare left ventricular (LV) volume and mass assessment using two‐dimensional (2D) cine steady‐state free precession (SSFP) and k‐t space broad‐use linear acquisition speed‐up technique (k‐t BLAST) accelerated 3D magnetic resonance imaging (MRI). ## Materials and Method
## Abstract ## Purpose To assess the feasibility and reproducibility of real‐time radial __k__‐__t__ sensitivity encoding (SENSE) magnetic resonance imaging (MRI) for biventricular volumetric assessment during exercise. ## Materials and Methods In all, 12 healthy young adults underwent MRI at re