A wire-crossed-loop resonator for rapid scan EPR
β Scribed by George A. Rinard; Richard W. Quine; Joshua R. Biller; Gareth R. Eaton
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 125 KB
- Volume
- 37B
- Category
- Article
- ISSN
- 1552-5031
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
A crossedβloop (orthogonal mode) resonator (CLR) was constructed of fine wire to achieve design goals for rapid scan in vivo EPR imaging at VHF frequencies (in practice, near 250 MHz). This application requires the resonator to have a very open design to facilitate access to the animal for physiological support during the image acquisition. The rapid scan experiment uses large amplitude magnetic field scans, and sufficiently large resonator and detection bandwidths to record the rapidlyβchanging signal response. Rapidβscan EPR is sensitive to RF/microwave source noise and to baseline changes that are coherent with the field scan. The sensitivity to source noise is a primary incentive for using a CLR to isolate the detected signal from the RF source noise. Isolation from source noise of 44 and 47 dB was achieved in two resonator designs. Prior results showed that eddy currents contribute to background problems in rapid scan EPR, so the CLR design had to minimize conducting metal components. Using fine (AWG 38) wire for the resonators decreased eddy currents and lowered the resonator Q, thus providing larger resonator bandwidth. Mechanical resonances at specific scan frequencies are a major contributor to rapid scan backgrounds. Β© 2010 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 37B: 86β91, 2010
π SIMILAR VOLUMES
Our crossed-loop resonator design has been enhanced to increase the filling factor and has been extended from S-band to L-band. High isolation between the two modes results in shorter dead time in pulsed EPR experiments than would occur with a reflection resonator of the same Q.
A new rectangular geometry of the loop-gap resonator for the use with a flat cell has been developed. Maxwell's equations for the resonators with two, four, six, and eight gaps have been solved assuming the existence of only the magnetic z-component. The formulas obtained were numerically solved for
The design and structure of a bridged loop-gap surface resonator developed for topical EPR spectroscopy and imaging of the distribution and metabolism of spin labels in in vivo skin is reported. The resonator is a one-loop, one-gap bridged structure. A pivoting single loop-coupling coil was used to
We report methodology which combines recently developed dielectric resonator-based, rapid-mix, stopped-flow EPR (appropriate for small, aqueous, lossy samples) with rapid scanning of the external (Zeeman) magnetic field where the scanning is preprogrammed to occur at selected times after the start o