A method for estimating vascular compliance using MR velocity imaging is presented. The technique combines an analysis of pulse propagation, based on spatially averaged equations of continuity and momentum, together with phase‐contrast velocity measurements to estimate the compliance from a correlation of second‐order spatial and temporal velocity derivatives. The technique can be applied in the presence of reflected flow waves and uses velocity data acquired throughout the entire cardiac cycle. The accuracy of the technique was assessed in distensible vessel phantoms spanning a physiological range of compliance through a comparison with compliance estimates obtained using high‐resolution MR imaging and pressure transducers. The mean error of all measurements was found to be 0.04 ±0.02% per mm Hg, with the relative errors ranging from 1.2% to 46%. Error was found to decrease as the temporal sampling rate and/or image plane separation were increased. This suggests that an accurate hemodynamic evaluation of a vessel's elastic properties is feasible with MR velocity imaging techniques.
📜 SIMILAR VOLUMES
## Abstract A method to measure arbitrary __k__‐space trajectories was developed to compensate for nonideal gradient performance during rapid magnetic resonance (MR) imaging with actively or nonactively shielded gradients at a magnetic field strength of 4.1 T. Accurate MR image reconstruction requi
## Abstract A new technique was designed and implemented that increases imaging speed in dynamic imaging in which change is restricted to a fraction of the full field of view (FOV). The technique is an enhancement of a reduced FOV method first reported by Hu and Parrish. This enhancement extends th
## Abstract ## Purpose To evaluate the reproducibility of a new multisite axial pulse wave velocity (PWV) measurement technique that makes use of 2D PCMR data and cross‐correlation analysis. ## Materials and Methods PWV was estimated with MRI in 13 healthy volunteers by a transit‐time technique
## Abstract ## Purpose To assess a method aimed at cutting histological specimens along the magnetic resonance (MR) imaging plane. ## Material and Methods The method is performed in two steps: the imaging plane (defined by three acrylic paint markers) is made horizontal under MR guidance by usin