𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A systematic study of the performance of the CsI:Tl single-crystal scintillator under X-ray excitation

✍ Scribed by Ioannis Valais; Dimitrios Nikolopoulos; Nektarios Kalivas; Anastasios Gaitanis; Georgios Loudos; Ioannis Sianoudis; Nikolaos Giokaris; Dionisis Cavouras; Nikolaos Dimitropoulos; Constantinos D. Nomicos; Ioannis Kandarakis; Georgios S. Panayiotakis


Publisher
Elsevier Science
Year
2007
Tongue
English
Weight
166 KB
Volume
571
Category
Article
ISSN
0168-9002

No coin nor oath required. For personal study only.

✦ Synopsis


The light emission performance of the X-ray excited CsI:Tl single-crystal scintillator was investigated as a function of X-ray tube voltage and crystal thickness. Four CsI:Tl single-crystal layers (CRYOS Ltd., Ukraine) with thickness from 1 to 7 mm were irradiated employing two X-ray tube voltage ranges: (i) the 22-45 kV (molybdenum anode-molybdenum filter (Mo/Mo)) range, employed in mammographic imaging and (ii) the 40-140 kV (tungsten anode-aluminum filter) tube voltage range, used in general X-ray projection and tomographic imaging. The X-ray luminescence efficiency (light emission spectrum over incident X-ray fluence) of the crystals was determined by performing light emission spectrum and X-ray exposure measurements. In addition, the intrinsic conversion efficiency (fraction of the absorbed X-ray converted into light) and the spectral compatibility to various optical detectors were estimated from these measurements. The luminescence efficiency was found to be a nonlinear function of crystal thickness and of X-ray tube voltage. Peak efficiency (29.5 mWm Γ€2 /mRs) was observed for the 5 mm thick crystal at 140 kV. A secondary efficiency peak was observed at 42 kV (Mo anode) probably due to the effect of the K-photoelectric absorption edge (at 33 and 35 keV for Cs and I, respectively). For the thicker (7 mm) crystal, the efficiency was found to decrease due to light attenuation effects within the scintillator mass.


πŸ“œ SIMILAR VOLUMES


ChemInform Abstract: Single Crystal X-Ra
✍ Junji Akimoto; Yasuhiko Takahashi; Yoshito Gotoh; Susumu Mizuta πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons βš– 29 KB πŸ‘ 1 views

## Abstract ChemInform is a weekly Abstracting Service, delivering concise information at a glance that was extracted from about 100 leading journals. To access a ChemInform Abstract of an article which was published elsewhere, please select a β€œFull Text” option. The original article is trackable v

Single crystal X-ray diffraction study o
✍ Y. Kudoh; H. Takeda πŸ“‚ Article πŸ“… 1986 πŸ› Elsevier Science βš– 225 KB

The effect of pressure on the bond compressibility in the crystal structures of fayalite, Fe2SiO 4 and rutile, TiO 2 were investigated by using a diamond anvil cell designed for this study and a four-circle single crystal X-ray diffractometer. The mean linear compressibilities of the Fe-O, Si-O and