## Abstract A surface‐enhanced Raman scattering (SERS)‐active microfluidic device with tunable surface plasmon resonances is presented here. It is constructed by silver grating substrates prepared by two‐beam laser interference of photoresists and subsequent metal evaporation coating, as well as PD
A surface plasmon resonance sensor on a compact disk-type microfluidic device
✍ Scribed by Akihide Hemmi; Takashi Usui; Akihiro Moto; Tatsuya Tobita; Nobuaki Soh; Koji Nakano; Hulie Zeng; Katsumi Uchiyama; Toshihiko Imato; Hizuru Nakajima
- Publisher
- John Wiley and Sons
- Year
- 2011
- Tongue
- English
- Weight
- 533 KB
- Volume
- 34
- Category
- Article
- ISSN
- 1615-9306
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A surface plasmon resonance (SPR) sensor on a compact disk (CD)‐type microfluidic device was developed to miniaturize the elements of a complete analytical system, pump and valves. The CD‐type microfluidic device was fabricated by attaching a polydimethylsiloxane disk plate that contained microchannels and reservoirs to a flat polycarbonate disk plate that contained grating films with a thin layer of Au. The optical system of the SPR sensor and the theory for its operation are based on the principle of a grating coupled‐type SPR. The sample and reagent solutions in the reservoirs on the CD‐type microfluidic device were sequentially introduced into the detection chamber by centrifugal force generated by the rotation of the microfluidic device. The variation of resonance wavelength was dependent on the refractive index of the sample solution. This CD‐type SPR sensor was successfully used in an immunoassay of immunoglobulin A (IgA). The anti‐IgA, blocking reagent, sample and washing solution in the reservoirs were sequentially introduced into the detection chamber by changing the frequency of rotation of the microfluidic device. IgA in the sample solution was adsorbed to the anti‐IgA immobilized on the Au thin layer in the detection chamber and was then detected by the SPR sensor.
📜 SIMILAR VOLUMES
## Abstract The Kretschmann‐type surface plasmon resonance (SPR) waveguide sensor is numerically investigated for detecting a change in the imaginary part of the refractive index. SPR responses are found to be quite sensitive to the change, suggesting the possibility of realizing a compact absorpti
A good basis has been established for the development of a prototype gas sensor using the phenomenon of surface plasmon resonance. By exciting a surface plasmon on a metallic diffraction grating that is twisted azimuthally so its grooves are not perpendicular to the plane of incidence, and with suit