A suggested cause of the fire-induced collapse of the World Trade Towers
β Scribed by J.G Quintiere; M di Marzo; R Becker
- Publisher
- Elsevier Science
- Year
- 2002
- Tongue
- English
- Weight
- 175 KB
- Volume
- 37
- Category
- Article
- ISSN
- 0379-7112
No coin nor oath required. For personal study only.
β¦ Synopsis
An analysis is presented that calculates the temperature of the steel truss rods in the World Trade Center towers subject to a fire based on the building ventilation factor. The CIB correlation is used for the fire. Conduction analyses are made taking into account variable properties for the steel and the insulation. A structural failure model is described based on compression buckling of the truss rods due to a reduction in the Young's modulus. The computed times for the estimated failure or incipient collapse of the floors in both towers has been computed as 105720 min for WTC 1 (north) and 5179 min for WTC 2 (south), compared to the collapse times from the aircraft impact of 104 and 56 min, respectively. The insulation thickness and the difference of 19.1 mm ( 3 4 00 ) and 38.1 mm (1 1 2 00 ) between the two towers appear to have been the root cause of the collapses.