𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A standardized experimental fracture in the mouse tibia

✍ Scribed by Ari Hiltunen; Eero Vuorio; Dr. Hannu T. Aro


Publisher
Elsevier Science
Year
1993
Tongue
English
Weight
684 KB
Volume
11
Category
Article
ISSN
0736-0266

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The increased use of transgenic mice as experimental animals provides new opportunities to study the biology of fracture repair. We have developed a technique for the production of a standard closed experimental fracture in the mouse tibia. A 0.2 mm stainless‐steel rod was introduced into the medullary cavity and the pre‐nailed tibial shaft was fractured by an impact device, which resulted in a reproducible transverse or slightly oblique fracture pattern. The intramedullary rod maintained axial alignment, and the fractures united without displacement. On the basis of measurements of callus geometry, four‐point bending tests, biochemical analyses, and quantitative histology, the progress of callus formation and remodeling occurred in a predictable sequence of healing phases. The ultimate bending loads of the fractures increased with time, reaching 74% of the strength of intact control tibias in 4 weeks. The stiffness values of the fractures returned to normal levels and, as determined radiographically, the fractures united by external callus in 4 weeks. Radiographically, callus size, cross‐sectional callus area, and callus mass peaked at 2 weeks and decreased thereafter, indicating the start of external remodeling. Histologically, the amount of mesenchymal tissue was maximal at days 5 and 7. The callus cartilage area peaked at day 9; at its maximum, it accounted for 46% of the total callus area. Early periosteal formation of membranous new bone, followed by endochondral ossification, resulted in a linear increase of callus bone during the healing process. The healing sequence of the mouse tibial fracture was similar to that seen in the rat tibia. The major difference is the small size of the mouse, which makes the surgical technique and anesthetic procedures more demanding.


πŸ“œ SIMILAR VOLUMES


In vivo cyclic axial compression affects
✍ Michael J. Gardner; Marjolein C. H. van der Meulen; Demetris Demetrakopoulos; Ti πŸ“‚ Article πŸ“… 2006 πŸ› Elsevier Science 🌐 English βš– 271 KB

## Abstract Abundant evidence exists that fracture healing can be influenced by mechanical loading. However, the specific loading parameters that are osteogenic remain unknown. We hypothesized that the bone healing response in mouse tibial osteotomies would be different with a short delay before lo

Contaminated fractures of the tibia: A c
✍ Mark J. Curtis; Phillip R. Brown; James D. Dick; Riyaz H. Jinnah πŸ“‚ Article πŸ“… 1995 πŸ› Elsevier Science 🌐 English βš– 973 KB

## Abstract External fixation is the current standard treatment for skeletal stabilization of open tibial fractures, but intramedullary fixation techniques have become increasingly popular. The aim of this study was to compare, in an animal model, the susceptibility to infection of contaminated fra

Determination of callus quantity in 4- w
✍ Dr. H. Aro; E. Eerola; A. J. Aho πŸ“‚ Article πŸ“… 1985 πŸ› Elsevier Science 🌐 English βš– 752 KB

In clinical practice the quantity of fracture callus is usually estimated on the basis of radiographs. In experimental studies on fracture healing, more exact chemical measurements (total protein, DNA, and mineral contents) have been used to quantitate the amount of callus. It is not known, however,