✦ Synopsis


A stopped-flow temperature-jump apparatus that has been used to extend the capabilities of a temperature-jump apparatus described previously (Verkman et al., Anal. Biochem. 102, 189-195, 1980) is described. The observation cell is a single cylinder made from ultraviolettransmitting Lucite. Stainless steel electrodes are fitted axially into each end of the cylinder, and solutions enter into and exit from the cylinder by passing through holes drilled perpendicular to the cylinder axis at the level of the electrodes. A triggering circuit provides a variable delay between solution mixing and the temperature-jump discharge. The mixing time for this instrument is under 1 ms, the dead time is under 60 ms, and the heating time is under 3 us. Solution reactions are followed by measuring optical absorption, fluorescence, or scattering with signal-to-noise ratios generally exceeding 5OO:l. The performance of this apparatus is illustrated by several membrane-substrate interactions.


📜 SIMILAR VOLUMES


Micellization Kinetics of a Novel Multi-
✍ Yanfeng Zhang; Tao Wu; Shiyong Liu 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 292 KB

## Abstract Double hydrophilic diblock copolymer, poly(__N__‐isopropylacrylamide)‐__block__‐poly(2‐diethylamino ethyl methacrylate) (PNIPAM‐__b__‐PDEA), was synthesized via reversible addition‐fragmentation chain transfer (RAFT) polymerization. Containing the well‐known thermo‐responsive PNIPAM blo

A combined nuclear magnetic resonance an
✍ William A. McGee; Lawrence J. Parkhurst 📂 Article 📅 1990 🏛 Elsevier Science 🌐 English ⚖ 818 KB

A combined NMR and absorbance stopped-flow has been developed for monitoring the kinetics of biochemical reactions. We demonstrate its usefulness in following the alkaline denaturation of human hemoglobin. No glassblowing is required in the fabrication of the apparatus. Commercially available valves

A simple, reliable rapid-mixing apparatu
✍ Lawrence C. Davis; Richard L. Cate; Thomas E. Roche 📂 Article 📅 1979 🏛 Elsevier Science 🌐 English ⚖ 751 KB

We have developed a simple and economical system for rapid mixing of solutions where a continuous-flow, chemically quenched mode of operation is appropriate. This has proved especially useful for studies of pyruvate dehydrogenase which produces a stable, enzymebound intermediate when the terminal ac