𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A simple and inexpensive turbidity meter for the estimation of suspended sediment concentrations

✍ Scribed by Damian M. Lawler; Robert M. Brown


Publisher
John Wiley and Sons
Year
1992
Tongue
English
Weight
749 KB
Volume
6
Category
Article
ISSN
0885-6087

No coin nor oath required. For personal study only.

✦ Synopsis


The relatively high cost of commercially available turbidity meters has inhibited detailed and intensive research on spatiotemporal patterns of suspended sediment transport. We describe here the electronic and physical design of an inexpensive turbidity sensor which is easy to construct, simple to interface with portable millivolt meters, dataloggers, computers, or chart recorders, consumes exceptionally small currents, and is robust and reliable. The very low individual cost allows a large number of sensors to be distributed throughout the water body of interest to facilitate turbidity mapping. Turbidity profilers to detect vertical or lateral turbidity changes in rivers, lakes, estuaries, or near-shore zones are also shown to be feasible. Test data are presented from a highly turbid glacial river in southern Iceland.


πŸ“œ SIMILAR VOLUMES


Estimating suspended sediment concentrat
✍ Jean P. G. Minella; Gustavo H. Merten; JosΓ© M. Reichert; Robin T. Clarke πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 658 KB

## Abstract __In situ__ turbidity meters are being increasingly used to generate continuous records of suspended sediment concentration in rivers. However, the usefulness of the information obtained depends heavily on the existence of a close relationship between fluctuations in suspended sediment

A simple and inexpensive multichannel po
✍ V. Rumenjak; I. Kruhak; S. MilardovΓ­c πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 219 KB πŸ‘ 1 views

A simple and reliable multichannel potentiometric analyzer for fully automatic determination of pH and concentration of sodium, potassium, calcium, and chloride ions in serum, and whole blood samples is described. The analyzer consists of five ion-selective electrodes (ISEs) as electrochemical senso

Estimation of suspended sediment loads i
✍ D. R. Moliere; K. G. Evans; M. J. Saynor; W. D. Erskine πŸ“‚ Article πŸ“… 2004 πŸ› John Wiley and Sons 🌐 English βš– 425 KB

## Abstract One year of instantaneous suspended sediment concentration, __C__, and instantaneous discharge, __Q__, data collected at Ngarradj downstream of the Jabiluka mine site indicate that the use of a simple __C__–__Q__ rating curve is not a reliable method for estimating suspended sediment lo