𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A sensitive and specific method for the determination of chlorimipramine and desmethylchlorimipramine in plasma using selected ion monitoring with chemical ionization

✍ Scribed by A. Lapin; M. Karobath


Publisher
John Wiley and Sons
Year
1980
Tongue
English
Weight
349 KB
Volume
7
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Chlorimipramine and other tricyclic antidepressant drugs are widely used for the treatment of depressive disorders. We analysed chlorimipramine and its major metabolite desmethylchlorimipramine after a two step extraction from plasma with diethylether. The underivatized samples were separated on a short (40 cm x 2 mm) silanized glass column packed with 3% OV 17 on Chromosorb HPW-DMCS, 80-100 mesh, which was directly coupled to the mass spectrometer. Detection of the tricyclic antidepressant drugs and their respective deuterium labelled internal standards was performed by chemical ionization using methanol vapour as reactant gas. The method is simple and sufficiently sensitive to permit the routine analysis of therapeutic plasma levels of tricyclic antidepressant drugs in extracts originating from 1 ml plasma.


πŸ“œ SIMILAR VOLUMES


A selected ion monitoring method for the
✍ Claes Lindberg; Margit Berg; Lars O. BorΓ©us; Per Hartvig; Karl-Erik Karlsson; Le πŸ“‚ Article πŸ“… 1978 πŸ› John Wiley and Sons 🌐 English βš– 357 KB πŸ‘ 1 views

An analytical procedure for the simultaneous determination of pethidine and norpethidine in plasma by selected ion monitoring is described. The method has a capacity of 15-20 analyses per hour and can be used to determine pethidine and norpethidine down to 25 ng ml-' and 5 ng ml-', respectively. The

A rapid and sensitive method for the qua
✍ Keyang Xu; Michael Lanuti; Eric S. Lambright; Seth D. Force; Steven M. Albelda; πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 77 KB πŸ‘ 2 views

A method using reversed-phase liquid chromatography coupled with electrospray ionization and selected reaction monitoring mass spectrometry has been developed for the quantitative analysis of ganciclovir in rat plasma. Acyclovir, a structurally related analog of ganciclovir, was used as the internal

Development and validation of a sensitiv
✍ Ravi Kumar Trivedi; Pramod Kumar Dubey; Ramesh Mullangi; Nuggehally R. Srinivas πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 397 KB πŸ‘ 2 views

## Abstract A highly sensitive and specific LC‐MS/MS method has been developed and validated for the estimation of torcetrapib (TTB) with 100 Β΅L hamster/dog plasma using DRL‐16126 as an internal standard (IS). The API‐4000 Q Trap LC‐MS/MS was operated under multiple‐reaction monitoring mode using t