๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

A Selective Procedure for DNA Extraction from Apoptotic Cells Applicable for Gel Electrophoresis and Flow Cytometry

โœ Scribed by J.P. Gong; F. Traganos; Z. Darzynkiewicz


Publisher
Elsevier Science
Year
1994
Tongue
English
Weight
554 KB
Volume
218
Category
Article
ISSN
0003-2697

No coin nor oath required. For personal study only.

โœฆ Synopsis


In cells undergoing apoptosis (programmed cell death), a fraction of nuclear DNA is fragmented to the size equivalent of DNA in mono- or oligonucleosomes. When such DNA is analyzed by agarose gel electrophoresis it generates the characteristic "ladder" pattern of discontinuous DNA fragments. Such a pattern of DNA degradation generally serves as a marker of the apoptotic mode of cell death. We developed a simple, rapid, and selective procedure for extraction of the degraded, low-molecular-weight DNA from apoptotic cells. The cells are prefixed in 70% ethanol, DNA is extracted with 0.2 M phosphate-citrate buffer at pH 7.8, and the extract is sequentially treated with RNase A and proteinase K and then subjected to electrophoresis. The ladder pattern was detected from DNA extracted from 1-2 x 10(6) HL-60 cells, of which as few as 8% were apoptotic, by flow cytometric criteria, as well as from blood and bone marrow samples from leukemic patients undergoing chemotherapy. The method is rapid and uses nontoxic reagents (no phenol, chloroform, etc.). This approach permits the analysis of DNA extracted from the very same cell population that is subjected to measurements by flow cytometry to estimate DNA ploidy, the cell cycle distribution of nonapoptotic cells, the percentage of apoptotic cells, or other parameters. Furthermore, the cells may be stored in 70% ethanol for at least several weeks before analysis without any significant DNA degradation. Treatment with ethanol also inactivates several pathogens, thereby increasing the safety of sample handling. The method is applicable to clinical samples, which can be fixed in ethanol and then stored and/or safety transported prior to analysis.


๐Ÿ“œ SIMILAR VOLUMES


A unified procedure for conservative (mo
โœ Maurizio Carbonari; Tiziana Tedesco; Massimo Fiorilli ๐Ÿ“‚ Article ๐Ÿ“… 2001 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 179 KB

## Background: Current methods for multiparameter dna flow cytometry suffer from several limitations. these include significant modifications of cell morphological parameters, the impossibility to counterstain cells with certain fluorochromes, and laborious tuning of the instrument that, for some p

A procedure for the extraction and high
โœ Peter C. Baciu; John P. Durham ๐Ÿ“‚ Article ๐Ÿ“… 1990 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 634 KB

A procedure for the extraction and high resolution two-dimensional gel electrophoresis of total nuclear phosphoproteins from isotonically purified nuclei Methods are described for the extraction and preparation of total nuclear proteins for high resolution two-dimensional polyacrylamide gel electrop